Smartphone-Interfaced Electrochemical Biosensor for microRNA Detection Based on Laser-Induced Graphene with π–π Stacked Peptide Nucleic Acid Probes
ACS Materials Letters · 04.03.2024 · 6 (3) · 837-846
DOI: 10.1021/acsmaterialslett.3c01225 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Materials Letters, online erschienen am 05.02.2024. Verfasst von Sharat Chandra Barman und 5 weiteren Autor:innen. Die Arbeit wurde bisher 56-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Abdullah University of Science and Technology, KAUST Smart Health Initiative.
Abstract (Originalsprache)
High Resolution Image Download MS PowerPoint Slide The development of ultrasensitive, rapid, and robust point-of-care devices for biomarker detection holds great promise to revolutionize clinical diagnostics. Notably, microRNA has demonstrated significant potential as a minimally invasive cancer biomarker; however, conventional approaches for their detection require costly multistep procedures, bulky equipment, and trained personnel. Herein, we develop a peptide nucleic acid (PNA)-functionalized laser-induced graphene biosensor based on a single-step fabrication and single-step probe functionalization strategy, with a smartphone-based readout. Immobilization of a bespoke 1-pyrenebutyryl-N-end-terminated 17 mer PNA through π–π stacking on graphene was validated via Raman and X-ray photoelectron spectroscopy. As a proof-of-concept, the biosensor is applied to the detection of a prostate cancer biomarker, hsa -miR-141, exhibiting excellent analytical performance with high specificity and a limit of detection of 0.6 aM, without requiring amplification, enzymes, or thermal cycling. The versatility of this portable amplification-free platform and its ease of fabrication facilitate its translation into a point-of-care device with the potential to revolutionize clinical diagnostics, even in resource-limited settings.
Förderung
- King Abdullah University of Science and Technology
- KAUST Smart Health Initiative
Zitieren
APA
Barman, S. C., Ali, M., Hasan, E. A., Wehbe, N., Alshareef, H. N., & Alsulaiman, D. (2024). Smartphone-Interfaced Electrochemical Biosensor for microRNA Detection Based on Laser-Induced Graphene with π–π Stacked Peptide Nucleic Acid Probes. ACS Materials Letters, 6(3), 837-846. https://doi.org/10.1021/acsmaterialslett.3c01225
Vancouver
Barman SC, Ali M, Hasan EA, Wehbe N, Alshareef HN, Alsulaiman D. Smartphone-Interfaced Electrochemical Biosensor for microRNA Detection Based on Laser-Induced Graphene with π–π Stacked Peptide Nucleic Acid Probes. ACS Materials Letters. 2024;6(3):837-846. doi:10.1021/acsmaterialslett.3c01225
BibTeX
@article{Barman2024,
author = {Barman, Sharat Chandra and Ali, Muhsin and Hasan, Erol A. and Wehbe, Nimer and Alshareef, Husam N. and Alsulaiman, Dana},
title = {Smartphone-Interfaced Electrochemical Biosensor for microRNA Detection Based on Laser-Induced Graphene with π–π Stacked Peptide Nucleic Acid Probes},
journal = {ACS Materials Letters},
year = {2024},
volume = {6},
number = {3},
pages = {837--846},
doi = {10.1021/acsmaterialslett.3c01225}
}
EUVIMED