Beyond Sensitivity: Materials and Biointerface Design Rules for Aptamer-Enabled Smart Contact Lenses
ACS Materials Au · 11.11.2026 · 6 (6) · 1197-1208
DOI: 10.1021/acsmaterialsau.6c00161 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift ACS Materials Au, online erschienen am 22.08.2026. Verfasst von Xiaolong Zhang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Device Center, Terasaki Institute for Biomedical Innovation, Los Angels, California 90064, United States. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Brain & Behavior Research Foundation NARSAD Young Investigator Grant.
Abstract (Originalsprache)
Smart contact lenses are emerging as platforms for continuous molecular monitoring at the ocular surface, yet their performance is often evaluated by detection limits measured in static buffer. During on-eye operation, signals are shaped before transduction by tear renewal, blinking, hydrogel partitioning, surface deposition, oxygen transport, receptor degradation, and interfacial drift. Aptamers offer sequence-defined recognition of metabolites, proteins, hormones, and drugs, but immobilization in hydrated lens materials can alter target accessibility, conformation, binding kinetics, and operational lifetime. In this perspective, we treat the tear–lens–aptamer biointerface as the functional sensing interface. We distinguish physiological concentration ranges, established lens benchmarks, and provisional engineering criteria, and examine flow, deformation, receptor saturation, nuclease stability, anchoring chemistry, fouling, optical and oxygen requirements, thermal effects, calibration, sterilization, shelf life, and regulatory considerations. This framework links material design to reversible, stable, and clinically interpretable measurements while preserving the optical, mechanical, and physiological performance required for a wearable lens.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Device Center, Terasaki Institute for Biomedical Innovation, Los Angels, California 90064, United States.
ORCID-Profile: Yangzhi Zhu
Förderung
- Brain & Behavior Research Foundation NARSAD Young Investigator Grant
Zitieren
APA
Zhang, X., & Zhu, Y. (2026). Beyond Sensitivity: Materials and Biointerface Design Rules for Aptamer-Enabled Smart Contact Lenses. ACS Materials Au, 6(6), 1197-1208. https://doi.org/10.1021/acsmaterialsau.6c00161
Vancouver
Zhang X, Zhu Y. Beyond Sensitivity: Materials and Biointerface Design Rules for Aptamer-Enabled Smart Contact Lenses. ACS Materials Au. 2026;6(6):1197-1208. doi:10.1021/acsmaterialsau.6c00161
BibTeX
@article{Zhang2026,
author = {Zhang, Xiaolong and Zhu, Yangzhi},
title = {Beyond Sensitivity: Materials and Biointerface Design Rules for Aptamer-Enabled Smart Contact Lenses},
journal = {ACS Materials Au},
year = {2026},
volume = {6},
number = {6},
pages = {1197--1208},
doi = {10.1021/acsmaterialsau.6c00161}
}
EUVIMED