EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Premise Plumbing “CT” (PPCT) as a Control Parameter for Opportunistic Pathogens

Tolulope O Odimayomi iD, Darel C Snead, William J Rhoads, Myra D Williams, Joseph O Falkinham, Amy Pruden iD, Marc A Edwards iD

ACS ES&T Water · 14.08.2026 · 6 (8) · 5398-5407

DOI: 10.1021/acsestwater.6c00582 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS ES&T Water, online erschienen am 23.07.2026. Verfasst von Tolulope O Odimayomi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States. Die Arbeit nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Virginia Polytechnic Institute and State University, Edna Bailey Sussman Foundation, National Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The product of disinfectant concentration and time (CT) is widely applied as a key pathogen inactivation parameter during potable water treatment. Here, we introduce the concept of premise plumbing CT (PPCT) as a part of an integrated framework for the control of opportunistic pathogens (OPs), such as Legionella pneumophila and Mycobacterium avium. A method is proposed for calculating CT at a given location in premise plumbing during stagnation events and demonstrated at scale in a chloraminated premise plumbing rig. Chloramine decay rates in stagnant PEX pipes were 2–3 orders of magnitude greater than in glass jars and dependent on initial chloramine concentration, contact time, temperature, pipe diameter, and flow rate. PPCT varied from 0 to 408 mg min/L from one pipe segment to another. No culturable L. pneumophila was detected in the test system pipes with PPCT > 78 mg min/L, which is comparable to reported CT thresholds for biofilm-associated L. pneumophila inactivation. Extending the concept to a lab-operated water heater yielded an estimated PPCT of 342.9 mg min/L, but robust growth of M. avium occurred in the tank up to 4 log CFU/mL, indicating extreme chloramine resistance. The PPCT framework introduced herein could provide a fundamental benchmark to help control OPs in the premise plumbing.

Schlagwörter

Stichwörter der Autor:innen

CT inactivationLegionella pneumophilaMycobacterium aviumpremise plumbing

Autor:innen und Institutionen

  • Via Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.
  • Department of Biological Sciences, Virginia Tech, Blacksburg, Virginia 24061, United States.

ORCID-Profile: Tolulope O Odimayomi, Amy Pruden, Marc A Edwards

Förderung

  • Virginia Polytechnic Institute and State University
  • Edna Bailey Sussman Foundation
  • National Science Foundation

Zitieren

APA

Odimayomi, T. O., Snead, D. C., Rhoads, W. J., Williams, M. D., Falkinham, J. O., Pruden, A., & Edwards, M. A. (2026). Premise Plumbing “CT” (PPCT) as a Control Parameter for Opportunistic Pathogens. ACS ES&T Water, 6(8), 5398-5407. https://doi.org/10.1021/acsestwater.6c00582

Vancouver

Odimayomi TO, Snead DC, Rhoads WJ, Williams MD, Falkinham JO, Pruden A, et al. Premise Plumbing “CT” (PPCT) as a Control Parameter for Opportunistic Pathogens. ACS ES&T Water. 2026;6(8):5398-5407. doi:10.1021/acsestwater.6c00582

BibTeX
@article{Odimayomi2026,
  author = {Odimayomi, Tolulope O and Snead, Darel C and Rhoads, William J and Williams, Myra D and Falkinham, Joseph O and Pruden, Amy and Edwards, Marc A},
  title = {Premise Plumbing “CT” (PPCT) as a Control Parameter for Opportunistic Pathogens},
  journal = {ACS ES&T Water},
  year = {2026},
  volume = {6},
  number = {8},
  pages = {5398--5407},
  doi = {10.1021/acsestwater.6c00582}
}