EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Antifouling Copper Surfaces Interfere with Wet Chemical Nitrate Sensors: Characterization and Mechanistic Investigation

Adrian M Nightingale iD, Alexander D Beaton iD, Antony J Birchill, Sharon Coleman, Gareth W H Evans, Sammer-Ul Hassan, Matthew C Mowlem, Xize Niu iD

ACS ES&T Water · 10.01.2025 · 5 (1) · 168-176

DOI: 10.1021/acsestwater.4c00749 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS ES&T Water, online erschienen am 17.12.2024. Verfasst von Adrian M Nightingale und 7 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, United Kingdom. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Councils UK.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wet chemical sensors autonomously sample and analyze water using chemical assays. Their internal fluidics are not susceptible to biofouling (the undesirable accumulation of microorganisms, algae, and animals in natural waters) due to the harsh chemical environment and dark conditions; however, the sample intake and filter are potentially susceptible. This paper describes the use of copper intake filters, incorporated to prevent fouling, on two different wet chemical nitrate sensors that each use different variants of the Griess assay (in particular, different nitrate reduction steps) to quantify nitrate concentrations. When the copper filters were used, measurements were perturbed in both sensors. Here we describe how the interference was first encountered in field testing and how it was subsequently replicated in laboratory testing. We show how the interference is due to the presence of copper ions from the filters and propose a mechanism for how it interferes with the assay, accounting for differences between the different versions of the Griess assay used in each sensor, and discuss strategies for its management. The findings are not just limited to wet chemical sensors but also more broadly applicable to any laboratory nitrate or nitrite analysis based on the Griess assay.

Autor:innen und Institutionen

  • Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, United Kingdom.
  • Ocean Technology and Engineering Group, National Oceanography Centre, Southampton, SO14 3ZH, United Kingdom.

ORCID-Profile: Adrian M Nightingale, Alexander D Beaton, Xize Niu

Förderung

  • Research Councils UK

Zitieren

APA

Nightingale, A. M., Beaton, A. D., Birchill, A. J., Coleman, S., Evans, G. W. H., Hassan, S. U., Mowlem, M. C., & Niu, X. (2025). Antifouling Copper Surfaces Interfere with Wet Chemical Nitrate Sensors: Characterization and Mechanistic Investigation. ACS ES&T Water, 5(1), 168-176. https://doi.org/10.1021/acsestwater.4c00749

Vancouver

Nightingale AM, Beaton AD, Birchill AJ, Coleman S, Evans GWH, Hassan SU, et al. Antifouling Copper Surfaces Interfere with Wet Chemical Nitrate Sensors: Characterization and Mechanistic Investigation. ACS ES&T Water. 2025;5(1):168-176. doi:10.1021/acsestwater.4c00749

BibTeX
@article{Nightingale2025,
  author = {Nightingale, Adrian M and Beaton, Alexander D and Birchill, Antony J and Coleman, Sharon and Evans, Gareth W H and Hassan, Sammer-Ul and Mowlem, Matthew C and Niu, Xize},
  title = {Antifouling Copper Surfaces Interfere with Wet Chemical Nitrate Sensors: Characterization and Mechanistic Investigation},
  journal = {ACS ES&T Water},
  year = {2025},
  volume = {5},
  number = {1},
  pages = {168--176},
  doi = {10.1021/acsestwater.4c00749}
}
Kostenlos starten →