A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments
ACS ES&T Air · 17.11.2026
DOI: 10.1021/acsestair.6c00341 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS ES&T Air, online erschienen am 17.11.2026. Verfasst von Junqi Li und 3 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Distinguishing outdoor atmospheric inputs from indoor sources is essential for understanding the environmental cycling of PM2.5-associated per- and polyfluoroalkyl substances (PFAS). We used a wildfire smoke episode as a natural perturbation to distinguish the relative contributions of outdoor atmospheric inputs and indoor sources to PM2.5-associated PFAS. Target ionic PFAS were measured simultaneously in indoor and outdoor PM2.5 and indoor dust from ten residences in Calgary, Canada, under normal and wildfire-affected conditions. Positive matrix factorization (PMF) was applied to identify source-related factors, with factor interpretation constrained by independent evidence from indoor–outdoor concentration gradients, correlation analyses, and compositional similarities. Despite substantial increases in PM2.5 loading during the wildfire period, total PM2.5-associated PFAS concentrations decreased by 80.6% indoors and 92.5% outdoors relative to normal conditions, revealing a pronounced decoupling between PM2.5 mass and associated PFAS. PMF identified two indoor source signatures: a legacy PFAS-related factor consistent with the historical use of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA), and a perfluoroalkyl carboxylic acid (PFCA)-rich factor potentially associated with more contemporary PFAS use, including alternative PFAS products. Under normal conditions, outdoor-related factors contributed 47.6% of indoor PM2.5-associated PFAS. During the wildfire period, this contribution decreased to 26.2%, while both indoor source signatures remained evident, suggesting continued indoor PFAS inputs, potentially including uptake of indoor-derived PFAS by infiltrating particles with relatively low PFAS concentrations. Overall, these findings demonstrate that transient atmospheric perturbations can facilitate the differentiation of indoor and outdoor source contributions to particle-associated contaminants. They also indicate that indoor air quality during wildfire events is jointly influenced by infiltrating smoke, persistent indoor contaminant sources, and their potential interactions with infiltrating particles.
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Li, J., Ma, Y., Xiong, Y., & Du, K. (2026). A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments. ACS ES&T Air. https://doi.org/10.1021/acsestair.6c00341
Vancouver
Li J, Ma Y, Xiong Y, Du K. A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments. ACS ES&T Air. 2026. doi:10.1021/acsestair.6c00341
BibTeX
@article{Li2026,
author = {Li, Junqi and Ma, Yulong and Xiong, Ying and Du, Ke},
title = {A Natural Perturbation Reveals Dynamic Source Attribution of PM2.5-Associated PFAS between Outdoor Atmosphere and Indoor Environments},
journal = {ACS ES&T Air},
year = {2026},
doi = {10.1021/acsestair.6c00341}
}
EUVIMED