Evaluating the Filtration and Breathability of Commercial Respiratory Devices for Potential Wildland and Wildland-Urban Interface Firefighting Operations

Melissa Armistead, Hannah Kirk, Emily Lowder, Warren Jasper, Cassandra Kwon, George Broyles, Matt Rahn, Kelcey Stricker, Rick Swan, R. Bryan Ormond

ACS ES&T Air · 16.11.2026

DOI: 10.1021/acsestair.6c00298 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS ES&T Air, online erschienen am 16.11.2026. Verfasst von Melissa Armistead und 9 weiteren Autor:innen. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: California Natural Resources Agency, U.S. Department of Homeland Security.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wildland firefighters are facing frequent and extreme wildfire behavior, placing them at greater risk for concentrated and cumulative inhalation exposures over each fire season. This study evaluated commercially available respirators and nontraditional respiratory devices to assess their potential use in wildland/wildland-urban interface (WUI) operations. Filter testing was conducted to identify devices with potential as barrier and/or protective face coverings under current respiratory standards. An animatronic headform was used to evaluate these devices alongside certified respirators through a simulated fit test to measure total filtration efficacy (TFE) and differential pressure (ΔP) at two breathing workloads. From these evaluations, the quality factor (qf) on the headform was predicted to be the most realistic measure of performance. Ultimately, no device was able to maintain qf ≥ 14 kPa–1 with TFE ≥ 50% and ΔP ≤ 5 mm H2O at both light and moderate workloads. Given the arduous workloads typical of wildland/WUI firefighting, this raises concerns about potential applications in the field. However, several of these devices maintained TFE ≥ 50% that could offer short-term solutions to help reduce exposure with intermittent use. More research is needed to ensure these proposed measures of TFE and ΔP are feasible without imposing a significant physiological burden.

Förderung

  • California Natural Resources Agency
  • U.S. Department of Homeland Security

Zitieren

APA

Armistead, M., Kirk, H., Lowder, E., Jasper, W., Kwon, C., Broyles, G., Rahn, M., Stricker, K., Swan, R., & Ormond, R. B. (2026). Evaluating the Filtration and Breathability of Commercial Respiratory Devices for Potential Wildland and Wildland-Urban Interface Firefighting Operations. ACS ES&T Air. https://doi.org/10.1021/acsestair.6c00298

Vancouver

Armistead M, Kirk H, Lowder E, Jasper W, Kwon C, Broyles G, et al. Evaluating the Filtration and Breathability of Commercial Respiratory Devices for Potential Wildland and Wildland-Urban Interface Firefighting Operations. ACS ES&T Air. 2026. doi:10.1021/acsestair.6c00298

BibTeX
@article{Armistead2026,
  author = {Armistead, Melissa and Kirk, Hannah and Lowder, Emily and Jasper, Warren and Kwon, Cassandra and Broyles, George and Rahn, Matt and Stricker, Kelcey and Swan, Rick and Ormond, R. Bryan},
  title = {Evaluating the Filtration and Breathability of Commercial Respiratory Devices for Potential Wildland and Wildland-Urban Interface Firefighting Operations},
  journal = {ACS ES&T Air},
  year = {2026},
  doi = {10.1021/acsestair.6c00298}
}
Kostenlos starten →