EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of a Hydrogen Full-Flow Sampling (H2FFS) System to Quantify Hydrogen Leak and Loss Emissions

Derek Johnson, Filiz Kazan, Christopher Ulishney, Christopher Loomis, David Childs, Scott Wayne, William Gillespie, David L. McKain, Nigel N. Clark

ACS ES&T Air · 11.09.2026 · 3 (9) · 2212-2224

DOI: 10.1021/acsestair.5c00517 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS ES&T Air, online erschienen am 21.08.2026. Verfasst von Derek Johnson und 8 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Environmental Defense Fund, Alfred P. Sloan Foundation, Grantham Foundation for the Protection of the Environment.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Though H2 is not a greenhouse gas, it has an impact on atmospheric chemistry that indirectly leads to warming. Because hydrogen is highly flammable, prior measurement efforts focused on safety. However, gauging the environmental impact of H2 emissions requires quantifying mass emission rates. We developed a full-flow sampling (FFS) system to quantify H2 emissions (H2FFS). We targeted an objective measurement uncertainty of ±15%. Various H2 concentration sensors were evaluated. Using controlled releases (full sample recovery tests─FSRTs), the H2FFS with its two electrochemical sensors demonstrated acceptable accuracy for H2 emissions from 0.5 to 10 g/h, while the H2FFS with its thermal conductivity demonstrated acceptable accuracy for H2 emissions from 100 to 500 g/h. The H2FFS with the spectral analyzer demonstrated acceptable accuracy for H2 emissions from 0.5 to 500 g/h. Leaks quantified during preliminary field testing at a H2 fueling station were found to range from 0.0 to 2.2 g/h, requiring accurate H2 measurement at the ppm level. Vent emissions were higher, which led to a modification of the system to include higher flow rates (up to 17 m3/min or 600 SCFM) and concentrations (up to 3%), but intermittent mass emissions were still higher than the calibrated range (>4.3 kg/h).

Förderung

  • Environmental Defense Fund
  • Alfred P. Sloan Foundation
  • Grantham Foundation for the Protection of the Environment
  • Three Cairns Group
  • Druckenmiller Foundation

Zitieren

APA

Johnson, D., Kazan, F., Ulishney, C., Loomis, C., Childs, D., Wayne, S., Gillespie, W., McKain, D. L., & Clark, N. N. (2026). Development of a Hydrogen Full-Flow Sampling (H2FFS) System to Quantify Hydrogen Leak and Loss Emissions. ACS ES&T Air, 3(9), 2212-2224. https://doi.org/10.1021/acsestair.5c00517

Vancouver

Johnson D, Kazan F, Ulishney C, Loomis C, Childs D, Wayne S, et al. Development of a Hydrogen Full-Flow Sampling (H2FFS) System to Quantify Hydrogen Leak and Loss Emissions. ACS ES&T Air. 2026;3(9):2212-2224. doi:10.1021/acsestair.5c00517

BibTeX
@article{Johnson2026,
  author = {Johnson, Derek and Kazan, Filiz and Ulishney, Christopher and Loomis, Christopher and Childs, David and Wayne, Scott and Gillespie, William and McKain, David L. and Clark, Nigel N.},
  title = {Development of a Hydrogen Full-Flow Sampling (H2FFS) System to Quantify Hydrogen Leak and Loss Emissions},
  journal = {ACS ES&T Air},
  year = {2026},
  volume = {3},
  number = {9},
  pages = {2212--2224},
  doi = {10.1021/acsestair.5c00517}
}
Kostenlos starten →