EUVIMEDEUVIMED entdecken
Crossref

3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits

Isteaque Ahmed, Andrew E Bryan, Shihab M Bhuiyan, Greg M Harris, Aashish Priye iD

ACS Biomaterials Science & Engineering · 10.11.2025 · 11 (11) · 6621-6632

DOI: 10.1021/acsbiomaterials.5c00814 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, online erschienen am 01.10.2025. Verfasst von Isteaque Ahmed und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Polyvinyls, Tissue Scaffolds, Stents. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: NINDS NIH HHS, U.S. Department of Health and Human Services.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peripheral nerve injuries present a critical clinical challenge, particularly when bridging larger defects that exceed the capacity of conventional grafts. Although electrospun poly(vinylidene fluoride-trifluoroethylene) (PVDF-TrFE) nerve guidance conduits (NGCs) provide a promising solution due to their piezoelectric properties and extracellular matrix-mimicking structure, in electrospun scaffold form, they lack the mechanical strength to resist luminal collapse and compressive forces from surrounding tissues. Here, we report a stent-inspired approach to reinforce PVDF-TrFE conduits by integrating 3D-printed polymer lattices composed of poly(ethylene glycol) diacrylate (PEGDA) and ethylene glycol polyether acrylate (EGPEA). By modulating the EGPEA:PEGDA ratio, we tailored the mechanical stiffness, swelling behavior, and ionic conductivity of the photocurable resin, yielding structural designs that effectively support PVDF-TrFE conduits. Mechanical testing and finite element analysis (FEA) demonstrated that hexagonal lattice geometries significantly reduced stress concentrations and enhanced yield strength under physiologically relevant pressures compared to rectangular controls. Additionally, the PEG moieties facilitated ion transport through the reinforcement structures, a property with the potential to modulate the local electrochemical environment and amplify the piezoelectric advantages of PVDF-TrFE. We demonstrated the resin's biocompatibility through fibroblast assays, showing no significant reduction in cell viability or morphological disruption compared to controls following a 24-h ethanol wash. Taken together, this work establishes a material-level proof-of-concept that integrates mechanical reinforcement with ionic transport in a piezoelectric conduit platform for enhanced peripheral nerve regeneration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalPolyvinylsTissue ScaffoldsStentsPolymersAnimalsPolyethylene GlycolsNerve RegenerationMiceElectric ConductivityBiocompatible MaterialsFluorocarbon Polymers

Stichwörter der Autor:innen

3D printingPEGDAPVDF-TrFEbiocompatibilityfinite element analysision conductivitymechanical reinforcementnerve guidance conduitsperipheral nerve regenerationpiezoelectric polymers

Substanzen

PolyvinylsPolyethylene GlycolsPolymersvinylidene fluoride-trifluoroethylene copolymerBiocompatible Materialspolyvinylidene fluoridepoly(ethylene glycol)diacrylateFluorocarbon Polymers

Autor:innen und Institutionen

  • Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States.
  • Medical Research Service, Cincinnati Veterans Affairs Medical Center, Cincinnati, Ohio 45220, United States.
  • Neuroscience Graduate Program, University of Cincinnati College of Medicine, Cincinnati, Ohio 45267, United States.
  • Department of Biomedical Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States.
  • Digital Futures, University of Cincinnati, Cincinnati, Ohio 45221, United States.

ORCID-Profile: Aashish Priye

Förderung

  • NINDS NIH HHS
  • U.S. Department of Health and Human Services

Zitieren

APA

Ahmed, I., Bryan, A. E., Bhuiyan, S. M., Harris, G. M., & Priye, A. (2025). 3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits. ACS Biomaterials Science & Engineering, 11(11), 6621-6632. https://doi.org/10.1021/acsbiomaterials.5c00814

Vancouver

Ahmed I, Bryan AE, Bhuiyan SM, Harris GM, Priye A. 3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits. ACS Biomaterials Science & Engineering. 2025;11(11):6621-6632. doi:10.1021/acsbiomaterials.5c00814

BibTeX
@article{Ahmed2025,
  author = {Ahmed, Isteaque and Bryan, Andrew E and Bhuiyan, Shihab M and Harris, Greg M and Priye, Aashish},
  title = {3D-Printed Stent-Like Polymeric Structures with Tunable Mechanical Properties and Ionic Conductivity for Reinforced Nerve Guidance Conduits},
  journal = {ACS Biomaterials Science & Engineering},
  year = {2025},
  volume = {11},
  number = {11},
  pages = {6621--6632},
  doi = {10.1021/acsbiomaterials.5c00814}
}
Kostenlos starten →