EUVIMEDEUVIMED entdecken
Crossref

Development of Polymer–Metal Screw System for Bone Fracture Repair: Combining Strength and Biocompatibility

Ranveer Kaur, Sunil Kumar Yadav, Vivek Yadav, Arnab Sikidar, Sanyog Jain iD, Dinesh Kalyanasundaram iD

ACS Biomaterials Science & Engineering · 2025

DOI: 10.1021/acsbiomaterials.5c00191 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, 2025. Verfasst von Ranveer Kaur und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Devices, National Institute of Pharmaceutical Education and Research, S.A.S. Nagar, Punjab 160062, India. Hauptthemen laut MEDLINE: Bone Screws, Polyurethanes, Polyesters, Biocompatible Materials. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Indian Council of Medical Research, Indian Institute of Technology Delhi, National Institute of Pharmaceutical Education and Research, Mohali.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Kein Abstract verfügbar.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone ScrewsPolyurethanesPolyestersBiocompatible MaterialsFractures, BonePolymersAlloysTitaniumAnimalsMaterials TestingHumansRats

Stichwörter der Autor:innen

acute systemic toxicitybioactivitycell differentiationfatigue bending strengthinjection moldinglocal effects after implantationorthopedic polymeric screwspolymer−metal screw system

Substanzen

PolyurethanesAlloysPolyestersTitaniumBiocompatible Materialspoly(lactide)titanium alloy (TiAl6V4)Polymers

Autor:innen und Institutionen

  • Department of Medical Devices, National Institute of Pharmaceutical Education and Research, S.A.S. Nagar, Punjab 160062, India.
  • Centre for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi 110016, India.
  • Centre for Pharmaceutical Nanotechnology, Department of Pharmaceutics, National Institute of Pharmaceutical Education and Research (NIPER), Sector 67, S.A.S. Nagar (Mohal), Punjab 160062, India.
  • Department of Biomedical Engineering, All India Institute of Medical Sciences, New Delhi 110029, India.

ORCID-Profile: Sanyog Jain, Dinesh Kalyanasundaram

Förderung

  • Indian Council of Medical Research
  • Indian Institute of Technology Delhi
  • National Institute of Pharmaceutical Education and Research, Mohali

Zitieren

APA

Kaur, R., Yadav, S. K., Yadav, V., Sikidar, A., Jain, S., & Kalyanasundaram, D. (2025). Development of Polymer–Metal Screw System for Bone Fracture Repair: Combining Strength and Biocompatibility. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.5c00191

Vancouver

Kaur R, Yadav SK, Yadav V, Sikidar A, Jain S, Kalyanasundaram D. Development of Polymer–Metal Screw System for Bone Fracture Repair: Combining Strength and Biocompatibility. ACS Biomaterials Science & Engineering. 2025. doi:10.1021/acsbiomaterials.5c00191

BibTeX
@article{Kaur2025,
  author = {Kaur, Ranveer and Yadav, Sunil Kumar and Yadav, Vivek and Sikidar, Arnab and Jain, Sanyog and Kalyanasundaram, Dinesh},
  title = {Development of Polymer–Metal Screw System for Bone Fracture Repair: Combining Strength and Biocompatibility},
  journal = {ACS Biomaterials Science & Engineering},
  year = {2025},
  doi = {10.1021/acsbiomaterials.5c00191}
}
Kostenlos starten →