Reduced Thermal Damage Achieved by High-Conductivity Hydrogel in RF Energy Tissue Welding
ACS Biomaterials Science & Engineering · 2025
DOI: 10.1021/acsbiomaterials.4c02292 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, 2025. Verfasst von Wenwen Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shang…. Hauptthemen laut MEDLINE: Hydrogels, Biocompatible Materials, Radio Waves. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Radiofrequency (RF) tissue welding is an innovative tissue anastomosis technique that utilizes bioimpedance to convert electrical energy into thermal energy, enabling the connection and reconstruction of tissues via the denaturation and crosslinking of proteins. However, the high temperatures generated in this process often lead to excessive thermal damage to tissues, thereby adversely impacting cellular activity and impeding tissue repair in practical applications. In this study, we developed a polyacrylamide/alginate (PAAm/Alg) hydrogel with high ionic conductivity (16.8 ± 1.2 S/m) achieved by introducing Ca2+ for the purpose of reducing thermal damage in RF tissue welding. The PAAm/Alg-Ca2+0.5M hydrogel possessed excellent mechanical properties with a stress of 315.6 ± 14.1 kPa and an elongation of 382.7 ± 89.0%. Additionally, the hydrogel exhibited a high water content (83.7 ± 0.3%) and excellent stability of swelling property in water. In addition, the hydrogel extract showed good biocompatibility with no significant adverse effects on cell activity in the cytotoxicity test. At last, we conducted ex vivo experiments to investigate the effectiveness of the hydrogel as a cooling agent during RF tissue welding. The result showed that the maximum temperature was effectively reduced from 137.9 ± 4.7 to 101.8 ± 2.5 °C, while the strength of the anastomotic stoma (12.0 ± 3.2 kPa) was not affected by the intervention of this hydrogel. Histological analysis also revealed that the anastomotic structure of the tissue with hydrogel intervention was more intact than that of the control. Thus, the PAAm/Alg-Ca2+0.5M hydrogel has been demonstrated to function effectively as a cooling agent, offering a new strategy for thermal damage control in RF tissue welding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Shanghai Institute for Minimally Invasive Therapy, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
ORCID-Profile: Lin Mao
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Zhang, W., Hu, Z., Yang, W., Chen, Y., Geng, Z., Song, C., & Mao, L. (2025). Reduced Thermal Damage Achieved by High-Conductivity Hydrogel in RF Energy Tissue Welding. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.4c02292
Vancouver
Zhang W, Hu Z, Yang W, Chen Y, Geng Z, Song C, et al. Reduced Thermal Damage Achieved by High-Conductivity Hydrogel in RF Energy Tissue Welding. ACS Biomaterials Science & Engineering. 2025. doi:10.1021/acsbiomaterials.4c02292
BibTeX
@article{Zhang2025,
author = {Zhang, Wenwen and Hu, Zhongxin and Yang, Wanwen and Chen, Yilong and Geng, Zhaoning and Song, Chengli and Mao, Lin},
title = {Reduced Thermal Damage Achieved by High-Conductivity Hydrogel in RF Energy Tissue Welding},
journal = {ACS Biomaterials Science & Engineering},
year = {2025},
doi = {10.1021/acsbiomaterials.4c02292}
}