Single-Particle Plasmon Sensor to Monitor Proteolytic Activity in Real Time
ACS Applied Optical Materials · 27.10.2023 · 1 (10) · 1661-1669
DOI: 10.1021/acsaom.3c00226 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Optical Materials, online erschienen am 04.10.2023. Verfasst von Rui Oliveira-Silva und 5 weiteren Autor:innen. Beteiligte Einrichtung: MBx Molecular Biosensing, Department of Applied Physics and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513…. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Funda??o para a Ci?ncia e a Tecnologia, H2020 European Research Council.
Abstract (Originalsprache)
We have established a label-free plasmonic platform that monitors proteolytic activity in real time. The sensor consists of a random array of gold nanorods that are functionalized with a design peptide that is specifically cleaved by thrombin, resulting in a blueshift of the longitudinal plasmon. By monitoring the plasmon of many individual nanorods, we determined thrombin's proteolytic activity in real time and inferred relevant kinetic parameters. Furthermore, a comparison to a kinetic model revealed that the plasmon shift is dictated by a competition between peptide cleavage and thrombin binding, which have opposing effects on the measured plasmon shift. The dynamic range of the sensor is greater than two orders of magnitude, and it is capable of detecting physiologically relevant levels of active thrombin down to 3 nM in buffered conditions. We expect these plasmon-mediated label-free sensors to open the window to a range of applications stretching from the diagnostic and characterization of bleeding disorders to fundamental proteolytic and pharmacological studies.
Autor:innen und Institutionen
- MBx Molecular Biosensing, Department of Applied Physics and Institute for Complex Molecular Systems, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven, The Netherlands.
- iBB - Institute for Biotechnology and Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal.
- Associate Laboratory i4HB-Institute for Health and Bioeconomy, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal.
- CQE-Centro de Química Estrutural, Institute of Molecular Sciences, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais 1, 1049-001 Lisboa, Portugal.
ORCID-Profile: Rui Oliveira-Silva, Yuyang Wang, Duarte M F Prazeres, Pedro M R Paulo, Peter Zijlstra
Förderung
- European Commission
- Funda??o para a Ci?ncia e a Tecnologia
- H2020 European Research Council
Zitieren
APA
Oliveira-Silva, R., Wang, Y., Nooteboom, S. W., Prazeres, D. M. F., Paulo, P. M. R., & Zijlstra, P. (2023). Single-Particle Plasmon Sensor to Monitor Proteolytic Activity in Real Time. ACS Applied Optical Materials, 1(10), 1661-1669. https://doi.org/10.1021/acsaom.3c00226
Vancouver
Oliveira-Silva R, Wang Y, Nooteboom SW, Prazeres DMF, Paulo PMR, Zijlstra P. Single-Particle Plasmon Sensor to Monitor Proteolytic Activity in Real Time. ACS Applied Optical Materials. 2023;1(10):1661-1669. doi:10.1021/acsaom.3c00226
BibTeX
@article{OliveiraSilva2023,
author = {Oliveira-Silva, Rui and Wang, Yuyang and Nooteboom, Sjoerd W and Prazeres, Duarte M F and Paulo, Pedro M R and Zijlstra, Peter},
title = {Single-Particle Plasmon Sensor to Monitor Proteolytic Activity in Real Time},
journal = {ACS Applied Optical Materials},
year = {2023},
volume = {1},
number = {10},
pages = {1661--1669},
doi = {10.1021/acsaom.3c00226}
}
EUVIMED