EUVIMEDEUVIMED entdecken
Crossref

Reduced Graphene Oxide−Carbon Nanotube Composite Fibers for Stable, High-Sensitivity Cryogenic Temperature Sensing

Huan Lin, Yuanjuan Zhang, Lijun Zhang, Shen Xu, Xinwei Wang

ACS Applied Nano Materials · 30.10.2026 · 9 (43) · 20387-20397

DOI: 10.1021/acsanm.6c04072 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Nano Materials, online erschienen am 20.10.2026. Verfasst von Huan Lin und 4 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Gefördert von: Natural Science Foundation of Qingdao Municipality, Natural Science Foundation of Shandong Province, National Basic Research Program of China (973 Program).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Resistive cryogenic temperature sensors based on metal-free carbon architectures are highly desirable for non-invasive thermal monitoring in quantum and aerospace systems, where minimal self-heating and rapid response are critical. Herein, we report reduced graphene oxide−multiwalled carbon nanotube composite fibers (rGOCFs) as an intrinsically self-sensing platform, wherein the mass ratio of graphene oxide (GO) to multiwalled carbon nanotube (MWCNT) is systematically engineered to tune low-temperature performance. Among the five compositions studied, a GO/MWCNT ratio of 16:6 gives the highest temperature coefficient of resistance (TCR), 0.15 K−1 (equivalent to 15% K−1) at 20 K, (over 75 times higher than that of platinum). It also features an ultrafast thermal response time of 0.23 s (sample 1; 0.44 s for sample 2) and minimal self-heating (ΔT < 1 K) in the 20−40 K range. Current-induced annealing preserves the R−T characteristics while healing structural defects and improving graphitic order, as indicated by XPS and thermal reffusivity analysis. This work demonstrates that compositional control in carbon-based composite fibers enables the concurrent improvement of sensitivity, response speed, and thermal stability, offering a promising route toward high-performance cryogenic temperature sensors.

Förderung

  • Natural Science Foundation of Qingdao Municipality
  • Natural Science Foundation of Shandong Province
  • National Basic Research Program of China (973 Program)
  • National Natural Science Foundation of China (NSFC)

Zitieren

APA

Lin, H., Zhang, Y., Zhang, L., Xu, S., & Wang, X. (2026). Reduced Graphene Oxide−Carbon Nanotube Composite Fibers for Stable, High-Sensitivity Cryogenic Temperature Sensing. ACS Applied Nano Materials, 9(43), 20387-20397. https://doi.org/10.1021/acsanm.6c04072

Vancouver

Lin H, Zhang Y, Zhang L, Xu S, Wang X. Reduced Graphene Oxide−Carbon Nanotube Composite Fibers for Stable, High-Sensitivity Cryogenic Temperature Sensing. ACS Applied Nano Materials. 2026;9(43):20387-20397. doi:10.1021/acsanm.6c04072

BibTeX
@article{Lin2026,
  author = {Lin, Huan and Zhang, Yuanjuan and Zhang, Lijun and Xu, Shen and Wang, Xinwei},
  title = {Reduced Graphene Oxide−Carbon Nanotube Composite Fibers for Stable, High-Sensitivity Cryogenic Temperature Sensing},
  journal = {ACS Applied Nano Materials},
  year = {2026},
  volume = {9},
  number = {43},
  pages = {20387--20397},
  doi = {10.1021/acsanm.6c04072}
}
Kostenlos starten →