EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Gold Electron Microscopy Grids with Anisotropic Foil Geometry Enable On-Grid Contact Guidance

Amit Avrahami, Noa Ben Asher, Ran Zalk, Nataliya Logvina iD, Leeya Engel iD

ACS Applied Materials & Interfaces · 28.10.2026 · 18 (42) · 57081-57090

DOI: 10.1021/acsami.6c12639 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 08.10.2026. Verfasst von Amit Avrahami und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering, Technion - Israel Institute of Technology, Haifa3200003, Israel. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Israel Science Foundation, Diane and Guilford Glazer Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

All-gold electron microscopy (EM) grids reduce beam-induced motion relative to conventional holey carbon supports and provide biocompatible substrates for cellular cryo-EM. However, placing customizable all-gold grid fabrication in the hands of researchers requires accessible processes based on standard microfabrication tools. We report a wafer-scale process using microfabrication techniques available in most academic cleanrooms, such as lift-off metallization, electroplating, and sacrificial layer release, to fabricate 594 all-gold grids per 4-inch wafer without individual grid handling. A numerical electroplating model provides a quantitative framework to relate gold deposition, grid-bar thickness, and tilt-compatible grid geometry. We show that oval 2 μm × 6 μm foil holes bias on-grid actin organization by substrate geometry alone, without chemical micropatterning. The EM grids supported a 2.15 Å apoferritin single-particle reconstruction on a 200 kV cryo-TEM and are compatible with protein micropatterning and cryo-electron tomography of cells. This platform establishes an accessible route to programmable, application-specific all-gold cryo-EM supports that couple high-resolution structural imaging with engineered control of cellular organization.

Schlagwörter

Stichwörter der Autor:innen

Cryo-EMCryo-ETEM gridsTEM gridscontact guidancegoldmanufacturingmicrofabrication

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering, Technion - Israel Institute of Technology, Haifa3200003, Israel.
  • Ilse Katz Institute for Nanoscale Science and Technology, Ben-Gurion University of the Negev, Beer Sheva8410501, Israel.
  • Resnick Sustainability Center for Catalysis, Technion - Israel Institute of Technology, Haifa3200003, Israel.

ORCID-Profile: Nataliya Logvina, Leeya Engel

Förderung

  • Israel Science Foundation
  • Diane and Guilford Glazer Foundation

Zitieren

APA

Avrahami, A., Ben Asher, N., Zalk, R., Logvina, N., & Engel, L. (2026). Gold Electron Microscopy Grids with Anisotropic Foil Geometry Enable On-Grid Contact Guidance. ACS Applied Materials & Interfaces, 18(42), 57081-57090. https://doi.org/10.1021/acsami.6c12639

Vancouver

Avrahami A, Ben Asher N, Zalk R, Logvina N, Engel L. Gold Electron Microscopy Grids with Anisotropic Foil Geometry Enable On-Grid Contact Guidance. ACS Applied Materials & Interfaces. 2026;18(42):57081-57090. doi:10.1021/acsami.6c12639

BibTeX
@article{Avrahami2026,
  author = {Avrahami, Amit and Ben Asher, Noa and Zalk, Ran and Logvina, Nataliya and Engel, Leeya},
  title = {Gold Electron Microscopy Grids with Anisotropic Foil Geometry Enable On-Grid Contact Guidance},
  journal = {ACS Applied Materials & Interfaces},
  year = {2026},
  volume = {18},
  number = {42},
  pages = {57081--57090},
  doi = {10.1021/acsami.6c12639}
}
Kostenlos starten →