Block Copolymer-Stabilized Complex Emulsions for Flow-Injection Detection of Perfluorooctanoic Acid in Multiple-Well Flow Chips
ACS Applied Materials & Interfaces · 26.08.2026 · 18 (33) · 45776-45789
DOI: 10.1021/acsami.6c11304 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 15.08.2026. Verfasst von Rakesh Narani und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, National Dong Hwa University, Shoufeng, Hualien974301, Taiwan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Dong Hwa University, Academia Sinica, National Tsing Hua University.
Abstract (Originalsprache)
Rapid, field-deployable screening methods are needed for per- and polyfluoroalkyl substances (PFAS), particularly in high-load and non-potable water streams. Here, we report a responsive complex-emulsion platform in which acid-reactive block copolymers (BCPs) stabilize hydrocarbon/fluorocarbon/water droplets and convert perfluorooctanoic acid (PFOA) binding into an optically readable change in morphology. Polystyrene-block-poly(4-vinylpyridine) (PS-b-P4VP) and polystyrene-block-poly(glycidyl methacrylate) (PS-b-PGMA) were synthesized by atom transfer radical polymerization and screened for interfacial activity and emulsion stability. The selected copolymers, PS2.4k-b-P4VP2.7k and PS2.5k-b-PGMA1.8k, reduced the hydrocarbon/water interfacial tension to 25.77 and 13.23 mN m–1, respectively, and stabilized fluorocarbon-in-hydrocarbon-in-water droplets. Exposure to PFOA transformed the droplets from engulfed to Janus morphologies. The response is consistent with pyridine protonation and pyridinium–perfluorooctanoate ion-pair formation in the PS-b-P4VP system and primarily hydrogen bonding, with a minor contribution from epoxide ring opening, in the PS-b-PGMA system. The morphology transition was retained in PFOA-spiked river water and was distinct from the responses to nonfluorinated carboxylic acids, humic acid, and sodium dodecyl sulfate. Integration with a multiple-well flow chip enabled concentration-dependent response times over 10–500 ppb PFOA, with PS-b-P4VP droplets reaching the Janus state in 1133 s at 10 ppb. A ResNet18 model classified droplet transitions with 92.8% accuracy, a weighted F1 score of 92.8%, and an area under the receiver operating characteristic curve of 0.98. This work establishes chemically programmed complex emulsions as dynamic optical transducers for rapid, semiquantitative PFOA screening.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, National Dong Hwa University, Shoufeng, Hualien974301, Taiwan.
- Institute of Chemistry, Academia Sinica , Nankang, Taipei115201, Taiwan.
- Department of Chemistry, National Chung Hsing University, Taichung City, 402202, Taiwan.
- Department of Chemistry, National Tsing Hua University, Hsinchu300044, Taiwan.
ORCID-Profile: Rakesh Narani, Hsiung-Lin Tu, Che-Jen Lin
Förderung
- National Dong Hwa University
- Academia Sinica
- National Tsing Hua University
- National Science and Technology Council
Zitieren
APA
Narani, R., Xie, M. F., Chou, T. F., Ho, G. S., Hung, W. C., Tu, H. L., Lee, C., & Lin, C. J. (2026). Block Copolymer-Stabilized Complex Emulsions for Flow-Injection Detection of Perfluorooctanoic Acid in Multiple-Well Flow Chips. ACS Applied Materials & Interfaces, 18(33), 45776-45789. https://doi.org/10.1021/acsami.6c11304
Vancouver
Narani R, Xie MF, Chou TF, Ho GS, Hung WC, Tu HL, et al. Block Copolymer-Stabilized Complex Emulsions for Flow-Injection Detection of Perfluorooctanoic Acid in Multiple-Well Flow Chips. ACS Applied Materials & Interfaces. 2026;18(33):45776-45789. doi:10.1021/acsami.6c11304
BibTeX
@article{Narani2026,
author = {Narani, Rakesh and Xie, Meng-Fu and Chou, Tsai-Fang and Ho, Guan-Sheng and Hung, Wei-Chin and Tu, Hsiung-Lin and Lee, Chuping and Lin, Che-Jen},
title = {Block Copolymer-Stabilized Complex Emulsions for Flow-Injection Detection of Perfluorooctanoic Acid in Multiple-Well Flow Chips},
journal = {ACS Applied Materials & Interfaces},
year = {2026},
volume = {18},
number = {33},
pages = {45776--45789},
doi = {10.1021/acsami.6c11304}
}