EUVIMEDEUVIMED entdecken
Crossref

Electrospun Cellulose Acetate Membranes Enable Low-Background Fluorescent Nanodiamond Lateral Flow Immunoassays for Highly Sensitive cTnI Detection

Zixuan Ren, Weimin Xu iD, Jiajia Zhao, Yue Cui iD

ACS Applied Materials & Interfaces · 05.08.2026 · 18 (30) · 40189-40199

DOI: 10.1021/acsami.6c02611 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 24.07.2026. Verfasst von Zixuan Ren und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing100871, P.R. Chin…. Hauptthemen laut MEDLINE: Cellulose, Nanodiamonds, Troponin I, Membranes, Artificial. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China, Beijing Science and Technology Planning Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lateral flow immunoassays (LFAs) are widely used because of their simplicity, rapid readout, and low cost; however, quantitative performance is often limited by insufficient signal intensity and background interference from the membrane substrate. This issue becomes more severe when high-brightness fluorescent nanolabels are introduced: conventional nitrocellulose (NC) membranes tend to exhibit autofluorescence and strong light scattering and can also promote nonspecific retention of nanoparticles, which elevates background and compromises quantitative reliability. Here, we present a “fluorescent nanodiamond–electrospun fibrous membrane” strategy, in which a fibrous electrospun cellulose acetate (ECA) membrane replaces the NC membrane and photostable nitrogen–vacancy center nanodiamonds (NVDs) serve as fluorescent labels. The uniform fibrous architecture of the ECA membrane reduces scattering and substrate-derived fluorescence; meanwhile, the fibrous network facilitates smoother convective wash-through, mitigating nonspecific adsorption and mechanical trapping of nanoparticles. As a result, unbound labels are more efficiently removed, leading to suppressed background signals and improved quantitative robustness. Using this platform, we achieved sensitive detection of cardiac troponin I (cTnI) with a limit of detection of ∼0.009 ng/mL, markedly better than conventional NC-based LFA strips. Clinical testing further confirms the diagnostic performance and consistency of the proposed approach. This work offers a simple route to enhance LFA sensitivity and quantification and is readily extendable to other point-of-care biosensing applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CelluloseNanodiamondsTroponin IMembranes, ArtificialImmunoassayHumansLimit of DetectionBiosensing TechniquesFluorescent Dyes

Stichwörter der Autor:innen

cellulose acetateelectrospunfluorescentlateral flow immunoassaynanodiamond

Substanzen

CelluloseNanodiamondsTroponin IacetylcelluloseMembranes, ArtificialFluorescent Dyes

Autor:innen und Institutionen

  • School of Materials Science and Engineering, State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University, Beijing100871, P.R. China.

ORCID-Profile: Weimin Xu, Yue Cui

Förderung

  • National Natural Science Foundation of China
  • National Key Research and Development Program of China
  • Beijing Science and Technology Planning Project
  • State Key Laboratory of Vascular Homeostasis and Remodeling, Peking University

Zitieren

APA

Ren, Z., Xu, W., Zhao, J., & Cui, Y. (2026). Electrospun Cellulose Acetate Membranes Enable Low-Background Fluorescent Nanodiamond Lateral Flow Immunoassays for Highly Sensitive cTnI Detection. ACS Applied Materials & Interfaces, 18(30), 40189-40199. https://doi.org/10.1021/acsami.6c02611

Vancouver

Ren Z, Xu W, Zhao J, Cui Y. Electrospun Cellulose Acetate Membranes Enable Low-Background Fluorescent Nanodiamond Lateral Flow Immunoassays for Highly Sensitive cTnI Detection. ACS Applied Materials & Interfaces. 2026;18(30):40189-40199. doi:10.1021/acsami.6c02611

BibTeX
@article{Ren2026,
  author = {Ren, Zixuan and Xu, Weimin and Zhao, Jiajia and Cui, Yue},
  title = {Electrospun Cellulose Acetate Membranes Enable Low-Background Fluorescent Nanodiamond Lateral Flow Immunoassays for Highly Sensitive cTnI Detection},
  journal = {ACS Applied Materials & Interfaces},
  year = {2026},
  volume = {18},
  number = {30},
  pages = {40189--40199},
  doi = {10.1021/acsami.6c02611}
}
Kostenlos starten →