Construction of a Fluorescence/Phase-Change Dual-Mode Sensor Based on Carbon Dots/Poly(acrylic acid) for Highly Selective and Sensitive Detection of Ferric Ions
ACS Applied Materials & Interfaces · 06.11.2024 · 16 (44) · 61036-61049
DOI: 10.1021/acsami.4c14018 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 22.10.2024. Verfasst von Yao Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Materials Science, Ludong University, Yantai 264025, China. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: Ludong University, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Fe3+ is one of the crucial metal ions in biological systems, and its excess or deficiency in the body can trigger various diseases, posing a serious threat to human health. Moreover, improper handling or disposal of Fe3+ can lead to water pollution, thereby harming the environment. Therefore, the development of highly selective and sensitive Fe3+ detection probes is particularly urgent. In this paper, a dual-mode sensor based on sol-gel and fluorescence signal responses was developed for the visual detection of Fe3+. The visual sensing method based on the simultaneous response of Fe3+-triggered dual signals can minimize the interference from false-positive signals and enhance detection accuracy. The dual-mode sensor, denoted as PAA@CDs, was constructed by incorporating high-brightness (high fluorescence emission intensity) green-yellow carbon dots (CDs) into poly(acrylic acid) (PAA), which possesses a large number of carboxyl functional groups. Based on the interaction of Fe3+ with the surface functional groups of CDs, nonfluorescent complexes are formed, leading to nonradiative electron transfer, which induces fluorescence quenching and produces a fluorescence signal visible to the naked eye. Additionally, the interaction of Fe3+ with the carboxyl groups of PAA triggers the cross-linking of PAA, causing a sol-gel phase change signal. Consequently, the PAA@CDs exhibit a dual-response signal in Fe3+ detection. Based on the fluorescence method, the linear detection range of PAA@CDs for Fe3+ is 0.05-2.60 mM with a limit of detection (LOD) of 5.14 μM. Meanwhile, using the sol-gel method, the linear detection range is 0.02-2.20 mM, and the LOD is 42.5 μM. Furthermore, the PAA@CDs probes can be successfully applied to the detection of Fe3+ in real water samples, demonstrating their potential value in the analysis of real samples containing multiple ions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Chemistry and Materials Science, Ludong University, Yantai 264025, China.
- Shandong Laboratory of Yantai Advanced Materials and Green Manufacturing, Yantai 264006, China.
ORCID-Profile: Xunyong Liu
Förderung
- Ludong University
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
- Key Technology Research and Development Program of Shandong Province
- Shandong Laboratory of Yantai Advanced Materials and Green Manufacturing
Zitieren
APA
Zhou, Y., Li, H., Gu, J., Fu, Y., Liu, J., Li, Z., Li, X., Liu, X., Qiao, Z., & Liu, Y. (2024). Construction of a Fluorescence/Phase-Change Dual-Mode Sensor Based on Carbon Dots/Poly(acrylic acid) for Highly Selective and Sensitive Detection of Ferric Ions. ACS Applied Materials & Interfaces, 16(44), 61036-61049. https://doi.org/10.1021/acsami.4c14018
Vancouver
Zhou Y, Li H, Gu J, Fu Y, Liu J, Li Z, et al. Construction of a Fluorescence/Phase-Change Dual-Mode Sensor Based on Carbon Dots/Poly(acrylic acid) for Highly Selective and Sensitive Detection of Ferric Ions. ACS Applied Materials & Interfaces. 2024;16(44):61036-61049. doi:10.1021/acsami.4c14018
BibTeX
@article{Zhou2024,
author = {Zhou, Yao and Li, Huidong and Gu, Junqi and Fu, Yonglin and Liu, Jingchun and Li, Zhaoyang and Li, Xinlong and Liu, Xunyong and Qiao, Zhuhui and Liu, Yi},
title = {Construction of a Fluorescence/Phase-Change Dual-Mode Sensor Based on Carbon Dots/Poly(acrylic acid) for Highly Selective and Sensitive Detection of Ferric Ions},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
volume = {16},
number = {44},
pages = {61036--61049},
doi = {10.1021/acsami.4c14018}
}
EUVIMED