An Implantable Self-Driven Diaphragm Pacing System Based on a Microvibration Triboelectric Nanogenerator for Phrenic Nerve Stimulation
ACS Applied Materials & Interfaces · 2024
DOI: 10.1021/acsami.4c03715 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, 2024. Verfasst von Hao Zhong und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, People's Republic of China. Hauptthemen laut MEDLINE: Phrenic Nerve, Diaphragm. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, Tianjin Medical University, Tianjin Health Key Discipline Special Project.
Abstract (Originalsprache)
Spinal cord injury poses considerable challenges, particularly in diaphragm paralysis. To address limitations in existing diaphragm pacing technologies, we report an implantable, self-driven diaphragm pacing system based on a microvibration triboelectric nanogenerator (MV-TENG). Leveraging the efficient MV-TENG, the system harvests micromechanical energy and converts this energy into pulses for phrenic nerve stimulation. In vitro tests confirm a stable MV-TENG output, while subcutaneous implantation of the device in rats results in a constant amplitude over 4 weeks with remarkable energy-harvesting efficacy. The system effectively induces diaphragmatic motor-evoked potentials, triggering contractions of the diaphragm. This proof-of-concept system has potential clinical applications in implantable phrenic nerve stimulation, presenting a novel strategy for advancing next-generation diaphragm pacing devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Tianjin Medical University General Hospital, Tianjin 300052, People's Republic of China.
- International Science and Technology Cooperation Base of Spinal Cord Injury, Tianjin 300052, People's Republic of China.
- Tianjin Key Laboratory of Spine and Spinal Cord Injury, Tianjin 300052, People's Republic of China.
- College of Electronic Information and Automation, Advanced Structural Integrity International Joint Research Center, Tianjin University of Science and Technology, Tianjin 300222, People's Republic of China.
ORCID-Profile: Zhigang Qu, Guangzhi Ning
Förderung
- National Natural Science Foundation of China
- Tianjin Medical University
- Tianjin Health Key Discipline Special Project
- Tianjin Key Medical Discipline Construction Project
Zitieren
APA
Zhong, H., Zhang, K., Zhou, M., Xing, C., An, Y., Zhang, Q., Guo, J., Liu, S., Qu, Z., Feng, S., & Ning, G. (2024). An Implantable Self-Driven Diaphragm Pacing System Based on a Microvibration Triboelectric Nanogenerator for Phrenic Nerve Stimulation. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.4c03715
Vancouver
Zhong H, Zhang K, Zhou M, Xing C, An Y, Zhang Q, et al. An Implantable Self-Driven Diaphragm Pacing System Based on a Microvibration Triboelectric Nanogenerator for Phrenic Nerve Stimulation. ACS Applied Materials & Interfaces. 2024. doi:10.1021/acsami.4c03715
BibTeX
@article{Zhong2024,
author = {Zhong, Hao and Zhang, Ke and Zhou, Mi and Xing, Cong and An, Yang and Zhang, Qi and Guo, Junrui and Liu, Song and Qu, Zhigang and Feng, Shiqing and Ning, Guangzhi},
title = {An Implantable Self-Driven Diaphragm Pacing System Based on a Microvibration Triboelectric Nanogenerator for Phrenic Nerve Stimulation},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
doi = {10.1021/acsami.4c03715}
}
EUVIMED