Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus
ACS Applied Materials & Interfaces · 08.11.2023 · 15 (44) · 52051-52064
DOI: 10.1021/acsami.3c14470 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 30.10.2023. Verfasst von Ji Hong Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Influenza viruses are known to cause pandemic flu outbreaks through both inter-human and animal-to-human transmissions. Therefore, the rapid and accurate detection of such pathogenic viruses is crucial for effective pandemic control. Here, we introduce a novel sensor based on affinity peptide-immobilized hydrogel microspheres for the selective detection of influenza A virus (IAV) H3N2. To enhance the binding affinity performance, we identified novel affinity peptides using phage display and further optimized their design. The functional hydrogel microspheres were constructed using the drop microfluidic technique, employing a structure composed of natural (chitosan) and synthetic (poly(ethylene glycol) diacrylate and PEG 6 kDa) polymers with the activation of azadibenzocyclooctyne for the subsequent click chemistry reaction. The binding peptide-immobilized hydrogel microsphere (BP-Hyd) was characterized by field emission scanning electron microscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy and exhibited selective detection capability for the IAV H3N2. To capture the detected IAV H3N2, a Cy3-labeled IAV hemagglutinin antibody was utilized. By incorporating the affinity peptide with hydrogel microspheres, we achieved quantitative and selective detection of IAV H3N2 with a detection limit of 1.887 PFU mL-1. Furthermore, the developed suspension sensor exhibited excellent reproducibility and showed reusability potential. Our results revealed that the BP-Hyd-based fluorescence sensor platform could be feasibly employed to detect other pathogens because the virus-binding peptides can be easily replaced with other peptides through phage display, enabling selective and sensitive binding to different targets.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Food Science and Technology, Chung-Ang University, Anseong 17546, Republic of Korea.
- School of Chemical Engineering, Yeungnam University, 280 Daehak-ro, Gyeongsan, Gyeongsangbuk-do 38541, Republic of Korea.
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Republic of Korea.
ORCID-Profile: Dae-Hyuk Kweon, Chang-Hyung Choi, Jong Pil Park
Förderung
- National Research Foundation of Korea
Zitieren
APA
Kim, J. H., Jeong, H. S., Hwang, J., Kweon, D. H., Choi, C. H., & Park, J. P. (2023). Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus. ACS Applied Materials & Interfaces, 15(44), 52051-52064. https://doi.org/10.1021/acsami.3c14470
Vancouver
Kim JH, Jeong HS, Hwang J, Kweon DH, Choi CH, Park JP. Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus. ACS Applied Materials & Interfaces. 2023;15(44):52051-52064. doi:10.1021/acsami.3c14470
BibTeX
@article{Kim2023,
author = {Kim, Ji Hong and Jeong, Hye-Seon and Hwang, Jaehyeon and Kweon, Dae-Hyuk and Choi, Chang-Hyung and Park, Jong Pil},
title = {Affinity Peptide-Tethered Suspension Hydrogel Sensor for Selective and Sensitive Detection of Influenza Virus},
journal = {ACS Applied Materials & Interfaces},
year = {2023},
volume = {15},
number = {44},
pages = {52051--52064},
doi = {10.1021/acsami.3c14470}
}
EUVIMED