EUVIMEDEUVIMED entdecken
Crossref

Smart Stimulation Response of a Pyrene-Based Lanthanide(III) MOF: Fluorescence Enhancement to HX (F and Cl) or R-COOH and Artificial Applicable Film on HCl Vapor Sensing

Rong Huo, Guang Zeng, Chen Wang, Yu Fei Wang, Yong Heng Xing iD, Feng Ying Bai iD

ACS Applied Materials & Interfaces · 01.11.2023 · 15 (43) · 50275-50289

DOI: 10.1021/acsami.3c11385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 20.10.2023. Verfasst von Rong Huo und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Liaoning Normal University, Dalian City 116029, P. R. China. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Department of Education of Liaoning Province, National Natural Science Foundation of China, Postgraduate Education Reform Project of Liaoning Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Toxic acids produced by industries are major hazards to the environment and human health, and luminescent pyrene-based crystalline metal-organic frameworks (MOFs) demonstrate promising performance in the detection of toxic acids. Herein, two novel isostructural 3D porous lanthanide MOFs, H3O·[Ln3(TBAPy)2(μ2-H2O)2(OH)2]·2DMA·2Diox·6.5H2O (Ln = Pr (1) and Ce (2); H4TBAPy (1,3,6,8-tetrakis(p-benzoic acid)pyrene); and DMA: N,N-dimethylacetamide) were synthesized, which showed alb topology. Based on the protonation and hydrogen bond mechanism, complex 1 could be used as a fluorescence recognition sensor for HX (X = F, Cl, Br, and I) acid solutions with different luminescence behaviors. It is worth noting that complex 1 exhibited high sensitivity in the fluorescence enhancement sensing of hydrofluoric acid, oxalic acid, and trichloroacetic acid. In particular, complex 1 had a low limit of detection (LOD) for OA (0.1 μM) and was applied to real monitoring of orange fruit samples. In addition, the PVA@1 film could selectively, sensitively, and quantitatively respond to hydrochloric acid (HCl) vapor through fluorescent quenching; due to its protonation and adsorption capacity, the LOD was 0.18 ppm. Therefore, the portable optical device, the PVA@1 film, can detect HCl gas in trace amounts, achieving the ultimate goal of real-time and rapid detection, which has potential application value for industrial production safety.

Schlagwörter

Stichwörter der Autor:innen

Ln-MOFartificial filmchemical sensingfluorescence enhancementpyrene derivativetoxic acids

Autor:innen und Institutionen

  • College of Chemistry and Chemical Engineering, Liaoning Normal University, Dalian City 116029, P. R. China.
  • State Key Laboratory of Catalysis, Dalian Institute of Chemical Physics, Chinese Academy of Science, Dalian 116023, P. R. China.

ORCID-Profile: Yong Heng Xing, Feng Ying Bai

Förderung

  • Department of Education of Liaoning Province
  • National Natural Science Foundation of China
  • Postgraduate Education Reform Project of Liaoning Province

Zitieren

APA

Huo, R., Zeng, G., Wang, C., Wang, Y. F., Xing, Y. H., & Bai, F. Y. (2023). Smart Stimulation Response of a Pyrene-Based Lanthanide(III) MOF: Fluorescence Enhancement to HX (F and Cl) or R-COOH and Artificial Applicable Film on HCl Vapor Sensing. ACS Applied Materials & Interfaces, 15(43), 50275-50289. https://doi.org/10.1021/acsami.3c11385

Vancouver

Huo R, Zeng G, Wang C, Wang YF, Xing YH, Bai FY. Smart Stimulation Response of a Pyrene-Based Lanthanide(III) MOF: Fluorescence Enhancement to HX (F and Cl) or R-COOH and Artificial Applicable Film on HCl Vapor Sensing. ACS Applied Materials & Interfaces. 2023;15(43):50275-50289. doi:10.1021/acsami.3c11385

BibTeX
@article{Huo2023,
  author = {Huo, Rong and Zeng, Guang and Wang, Chen and Wang, Yu Fei and Xing, Yong Heng and Bai, Feng Ying},
  title = {Smart Stimulation Response of a Pyrene-Based Lanthanide(III) MOF: Fluorescence Enhancement to HX (F and Cl) or R-COOH and Artificial Applicable Film on HCl Vapor Sensing},
  journal = {ACS Applied Materials & Interfaces},
  year = {2023},
  volume = {15},
  number = {43},
  pages = {50275--50289},
  doi = {10.1021/acsami.3c11385}
}
Kostenlos starten →