Carbon Nanotube Field-Effect Transistor Biosensor with an Enlarged Gate Area for Ultra-Sensitive Detection of a Lung Cancer Biomarker
ACS Applied Materials & Interfaces · 07.06.2023 · 15 (22) · 27299-27306
DOI: 10.1021/acsami.3c02700 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 26.05.2023. Verfasst von Luyao Li und 7 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan 411105, China. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Lung Neoplasms, Biosensing Techniques. Die Arbeit wurde bisher 59-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of?Hunan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Carcinoembryonic antigen (CEA) is a recognized biomarker for lung cancer and can be used for early detection. However, the clinical value of CEA is not fully realized due to the rigorous requirement for high-sensitivity and wide-range detection methods. Field-effect transistor (FET) biosensors, as one of the potentially powerful platforms, may detect CEA with a significantly higher sensitivity than conventional clinical testing equipment, while their sensitivity and detection range for CEA are far below the requirement for early detection. Here, we construct a floating gate FET biosensor to detect CEA based on a semiconducting carbon nanotube (CNT) film combined with an undulating yttrium oxide (Y2O3) dielectric layer as the biosensing interface. Utilizing an undulating biosensing interface, the proposed device showed a wider detection range and optimized sensitivity and detection limit, which benefited from an increase of probe-binding sites on the sensing interface and an increase of electric double-layer capacitance, respectively. The outcomes of analytical studies confirm that the undulating Y2O3 provided the desired biosensing surface for probe immobilization and performance optimization of a CNT-FET biosensor toward CEA including a wide detection range from 1 fg/mL to 1 ng/mL, good linearity, and high sensitivity of 72 ag/mL. More crucially, the sensing platform can function normally in the complicated environment of fetal bovine serum, indicating its great promise for early lung cancer screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Hunan 411105, China.
- Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-based Electronics, School of Electronics, Peking University, Beijing 100871, China.
ORCID-Profile: Xiaofeng Liu, Tongye Wei, Yiwei Liu, Zhiyong Zhang
Förderung
- Natural Science Foundation of?Hunan Province
- National Natural Science Foundation of China
Zitieren
APA
Li, L., Liu, X., Wei, T., Wang, K., Zhao, Z., Cao, J., Liu, Y., & Zhang, Z. (2023). Carbon Nanotube Field-Effect Transistor Biosensor with an Enlarged Gate Area for Ultra-Sensitive Detection of a Lung Cancer Biomarker. ACS Applied Materials & Interfaces, 15(22), 27299-27306. https://doi.org/10.1021/acsami.3c02700
Vancouver
Li L, Liu X, Wei T, Wang K, Zhao Z, Cao J, et al. Carbon Nanotube Field-Effect Transistor Biosensor with an Enlarged Gate Area for Ultra-Sensitive Detection of a Lung Cancer Biomarker. ACS Applied Materials & Interfaces. 2023;15(22):27299-27306. doi:10.1021/acsami.3c02700
BibTeX
@article{Li2023,
author = {Li, Luyao and Liu, Xiaofeng and Wei, Tongye and Wang, Kemin and Zhao, Zijun and Cao, Juexian and Liu, Yiwei and Zhang, Zhiyong},
title = {Carbon Nanotube Field-Effect Transistor Biosensor with an Enlarged Gate Area for Ultra-Sensitive Detection of a Lung Cancer Biomarker},
journal = {ACS Applied Materials & Interfaces},
year = {2023},
volume = {15},
number = {22},
pages = {27299--27306},
doi = {10.1021/acsami.3c02700}
}
EUVIMED