Stiffness-Dependent Mechanotransductive Signaling in Silicone Implant-Associated Fibrotic Encapsulation
ACS Applied Bio Materials · 2026
DOI: 10.1021/acsabm.6c01259 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2026. Verfasst von Jun Ho Park und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-ro 5-gil,…. Hauptthemen laut MEDLINE: Mechanotransduction, Cellular, Biocompatible Materials, Silicones, Prostheses and Implants. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Seoul National University Hospital Research Fund, National Research Foundation of Korea (NRF) grant, Korean government (MSIT), Seoul Metropolitan Government?Seoul National University Boramae Medical Center Research Fund.
Abstract (Originalsprache)
Fibrotic encapsulation remains a major limitation of silicone-based soft-tissue implants and contributes to capsular contracture. Although biochemical and immunological factors have been extensively investigated, the contribution of implant stiffness to the peri-implant foreign body response remains incompletely defined. Here, we evaluated whether silicone implant stiffness is associated with fibrotic remodeling and changes in mechanotransductive signaling. Polydimethylsiloxane (PDMS) substrates and implants with elastic moduli ranging from 60 to 2000 kPa were fabricated and examined using human dermal fibroblasts and a rat subcutaneous implantation model. Increasing stiffness was associated with enhanced β1 integrin expression, FAK phosphorylation, ROCK1 expression, actin cytoskeletal organization, nuclear YAP localization, and upregulation of profibrotic markers, including α-SMA, CTGF, COL1A1, and COL3A1. In vivo, stiffer implants showed greater capsule thickness, collagen deposition, inflammatory cell infiltration, MPO and TGF-β1 expression, and sustained stiffness-associated changes in mechanotransductive proteins at 4 and 12 weeks. In contrast, the most compliant silicone condition attenuated these fibrosis-associated responses. These findings support material stiffness as a modifiable design parameter for silicone-based implantable biomaterials and suggest that relative softening within a feasible silicone material range may help reduce peri-implant fibrotic encapsulation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20 Boramae-ro 5-gil, Dongjak-gu07061, Republic of Korea.
- Department of Chemistry, College of Natural Sciences, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul08826, Republic of Korea.
ORCID-Profile: Jun Ho Park, Yan Lee
Förderung
- Seoul National University Hospital Research Fund
- National Research Foundation of Korea (NRF) grant, Korean government (MSIT)
- Seoul Metropolitan Government?Seoul National University Boramae Medical Center Research Fund
Zitieren
APA
Park, J. H., Lee, M. H., Kim, K. M., Lee, Y., & Park, J. U. (2026). Stiffness-Dependent Mechanotransductive Signaling in Silicone Implant-Associated Fibrotic Encapsulation. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.6c01259
Vancouver
Park JH, Lee MH, Kim KM, Lee Y, Park JU. Stiffness-Dependent Mechanotransductive Signaling in Silicone Implant-Associated Fibrotic Encapsulation. ACS Applied Bio Materials. 2026. doi:10.1021/acsabm.6c01259
BibTeX
@article{Park2026,
author = {Park, Jun Ho and Lee, Mi Hyun and Kim, Ki-Myo and Lee, Yan and Park, Ji-Ung},
title = {Stiffness-Dependent Mechanotransductive Signaling in Silicone Implant-Associated Fibrotic Encapsulation},
journal = {ACS Applied Bio Materials},
year = {2026},
doi = {10.1021/acsabm.6c01259}
}
EUVIMED