Fabrication of a Silk-Glycerol-Based Flexible Electrode Decorated with WO3 Nanorods for Ultrasensitive Electrochemical Detection of Bacteria
ACS Applied Bio Materials · 2026
DOI: 10.1021/acsabm.6c00464 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2026. Verfasst von Karri Trinadha Rao und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, Sangareddy, Kandi, Telangana502284, India. Hauptthemen laut MEDLINE: Tungsten, Glycerol, Escherichia coli, Oxides. Die Arbeit nennt 64 Literaturangaben. Gefördert von: Nano Mission Council, Department of Science and Technology.
Abstract (Originalsprache)
This paper reports the preparation and characterization of a silk-glycerol composite-based, biocompatible, optically transparent, and flexible substrate. Blending glycerol with silk not only eliminates the brittleness of pure silk films but also enhances flexibility and long-term mechanical stability. Its applicability in the electrochemical detection of Escherichia coli (E. coli) bacteria on a screen-printed electrode system is a testament to the robustness of the substrate. To improve the sensitivity and selectivity of E. coli detection, the working electrode is modified with amine-functionalized WO3 nanorods. The developed flexible biosensor platform selectively detects the targeted E. coli bacteria sample, even in mixed bacterial cultures and fungal strains, with an ultralow detection limit of 0.15 CFU/mL, and at the same time, it has a wide detection range starting from 0.15 to 1.5 × 104 CFU/mL. The repeatability, stability, and specificity studies in real samples affirmatively indicate its potential for usage in clinical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical Engineering, Indian Institute of Technology, Hyderabad, Sangareddy, Kandi, Telangana502284, India.
- Department of Chemistry, Indian Institute of Technology, Hyderabad, Sangareddy, Kandi, Telangana502284, India.
- Department of Biomedical Engineering, Indian Institute of Technology, Hyderabad, Sangareddy, Kandi, Telangana502284, India.
- Department of Materials Science & Metallurgical Engineering, Indian Institute of Technology, Hyderabad, Sangareddy, Kandi, Telangana502284, India.
ORCID-Profile: Pravat Kumar Sahu, Aravind Kumar Rengan, Subrahmanyam Challapalli, Siva Rama Krishna Vanjari
Förderung
- Nano Mission Council, Department of Science and Technology
Zitieren
APA
Rao, K. T., Sahu, P. K., Kandala, A. B., G N, K., Gangwar, R., Beniwal, N., Rengan, A. K., Challapalli, S., Garlapati, S. K., & Vanjari, S. R. K. (2026). Fabrication of a Silk-Glycerol-Based Flexible Electrode Decorated with WO3 Nanorods for Ultrasensitive Electrochemical Detection of Bacteria. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.6c00464
Vancouver
Rao KT, Sahu PK, Kandala AB, G N K, Gangwar R, Beniwal N, et al. Fabrication of a Silk-Glycerol-Based Flexible Electrode Decorated with WO3 Nanorods for Ultrasensitive Electrochemical Detection of Bacteria. ACS Applied Bio Materials. 2026. doi:10.1021/acsabm.6c00464
BibTeX
@article{Rao2026,
author = {Rao, Karri Trinadha and Sahu, Pravat Kumar and Kandala, Aditya Bhagavathi and G N, Kokila and Gangwar, Rahul and Beniwal, Nitisha and Rengan, Aravind Kumar and Challapalli, Subrahmanyam and Garlapati, Suresh Kumar and Vanjari, Siva Rama Krishna},
title = {Fabrication of a Silk-Glycerol-Based Flexible Electrode Decorated with WO3 Nanorods for Ultrasensitive Electrochemical Detection of Bacteria},
journal = {ACS Applied Bio Materials},
year = {2026},
doi = {10.1021/acsabm.6c00464}
}
EUVIMED