EUVIMEDEUVIMED entdecken
Crossref

Dynamic Cardiac Health Monitoring Using Polymer-Embedded Reconfigurable Fiber Cavity

Pratik Mishra iD, Balamurugan Ramadass, Prasant Nayak, Rajan Jha iD

ACS Applied Bio Materials · 2026

DOI: 10.1021/acsabm.5c02174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2026. Verfasst von Pratik Mishra und 3 weiteren Autor:innen. Beteiligte Einrichtung: Nanophotonics and Plasmonics Laboratory, School of Basic Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha752050, India. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Polymers, Biocompatible Materials, Optical Fibers. Die Arbeit nennt 40 Literaturangaben. Gefördert von: National Technical Textiles Mission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of human pulse signals is crucial for assessing cardiovascular health and detecting early signs of heart disorders. In this context, wearable systems offer a promising platform for continuous cardiac monitoring; however, existing devices suffer from complex fabrication, low accuracy, and limited body placement flexibility apart from bio-compatibility issues. To address these challenges, a wearable pulse monitoring system based on a flexible optical cavity has been developed and validated. The design employs a flexible polymer for both the cavity and the encapsulating material, enhancing mechanical strength and sensitivity compared to fiber cavity-based systems. The proposed device features a user-friendly and simple fabrication process and exhibits a high sensitivity of 610 pm/V under forced vibration, with a detection capability down to 0.1 Hz, enabling precise capture of subtle pulse wave impulses. Furthermore, it successfully monitors pulse signals from multiple body sites such as the wrist, elbow, and fingertip while distinguishing main, dicrowave, and tidal peaks. Its temperature stability and reliable performance under mild human motion, including arm movement, slow walking, and fast walking, even after physical activity, highlight its strong potential for continuous and practical cardiac health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesPolymersBiocompatible MaterialsOptical FibersHumansMonitoring, PhysiologicMaterials TestingParticle SizeDigital Health

Stichwörter der Autor:innen

cardiac health monitoringfiber cavityhuman pulse detectionoptical sensorreal-time monitoring

Substanzen

PolymersBiocompatible Materials

Autor:innen und Institutionen

  • Nanophotonics and Plasmonics Laboratory, School of Basic Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha752050, India.
  • Department of Biochemistry, All India Institute of Medical Sciences Bhubaneswar, Bhubaneswar, Odisha751019, India.
  • Department of Urology, All India Institute of Medical Sciences Bhubaneswar, Bhubaneswar, Odisha751019, India.

ORCID-Profile: Pratik Mishra, Rajan Jha

Förderung

  • National Technical Textiles Mission

Zitieren

APA

Mishra, P., Ramadass, B., Nayak, P., & Jha, R. (2026). Dynamic Cardiac Health Monitoring Using Polymer-Embedded Reconfigurable Fiber Cavity. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.5c02174

Vancouver

Mishra P, Ramadass B, Nayak P, Jha R. Dynamic Cardiac Health Monitoring Using Polymer-Embedded Reconfigurable Fiber Cavity. ACS Applied Bio Materials. 2026. doi:10.1021/acsabm.5c02174

BibTeX
@article{Mishra2026,
  author = {Mishra, Pratik and Ramadass, Balamurugan and Nayak, Prasant and Jha, Rajan},
  title = {Dynamic Cardiac Health Monitoring Using Polymer-Embedded Reconfigurable Fiber Cavity},
  journal = {ACS Applied Bio Materials},
  year = {2026},
  doi = {10.1021/acsabm.5c02174}
}
Kostenlos starten →