Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers
ACS Applied Bio Materials · 15.09.2025 · 8 (9) · 8250-8260
DOI: 10.1021/acsabm.5c01212 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Bio Materials, online erschienen am 08.08.2025. Verfasst von Hafiza Kanza Maryam und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore 54590, Pakistan. Hauptthemen laut MEDLINE: Oxidative Stress, Tyrosine, Polymers, Electrochemical Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Royal Society of Chemistry.
Abstract (Originalsprache)
3-Nitro-l-tyrosine (NO2Tyr) serves as a critical biomarker of oxidative stress, closely linked to the pathogenesis of neurodegenerative and inflammatory disorders. This study presents a highly sensitive and selective nonenzymatic electrochemical sensor that uses polymer nanozyme properties for the detection of NO2Tyr in human saliva. The sensor design integrates molecularly imprinted poly(3-aminophenol) (MIP) films, electropolymerized directly onto graphitic electrodes (GPE) via cyclic voltammetry (CV), with NO2Tyr acting as the molecular template. By mimicking enzyme-substrate recognition, the MIP/GPE sensor exhibits superior electrochemical performance without relying on biological enzymes. Surface analysis confirms uniform MIP film formation, while electrochemical characterization reveals a significant reduction in charge transfer resistance and enhanced electroactive surface area, facilitating rapid electron transfer critical for sensitive NO2Tyr detection. Sensor measurements reveal a linear detection range of 0-1000 nM, a low limit of detection (LOD) of 0.21 nM, and a sensitivity of 0.94 μA cm-2 nM-1 toward NO2Tyr. The sensor maintains high selectivity against common salivary interferents, including structurally similar l-tyrosine (Tyr), and achieves an overall 95.9% recovery rate in different human saliva samples. This MIP-based sensing platform introduces an effective enzyme-mimetic strategy for selective NO2Tyr recognition, offering a robust, disposable, and cost-efficient tool for point-of-care (PoC) monitoring of oxidative stress biomarkers. Its operational simplicity, stability, and compatibility with complex biological fluids position it as a promising candidate for early stage screening and management of oxidative stress-associated neurodegenerative diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Sensors and Diagnostics Lab, School of Chemistry, University of the Punjab, Quaid-i-Azam Campus, Lahore 54590, Pakistan.
ORCID-Profile: Adnan Mujahid, Adeel Afzal
Förderung
- Royal Society of Chemistry
Zitieren
APA
Maryam, H. K., Mujahid, A., & Afzal, A. (2025). Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers. ACS Applied Bio Materials, 8(9), 8250-8260. https://doi.org/10.1021/acsabm.5c01212
Vancouver
Maryam HK, Mujahid A, Afzal A. Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers. ACS Applied Bio Materials. 2025;8(9):8250-8260. doi:10.1021/acsabm.5c01212
BibTeX
@article{Maryam2025,
author = {Maryam, Hafiza Kanza and Mujahid, Adnan and Afzal, Adeel},
title = {Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers},
journal = {ACS Applied Bio Materials},
year = {2025},
volume = {8},
number = {9},
pages = {8250--8260},
doi = {10.1021/acsabm.5c01212}
}