Artificial Tendons’ Responsiveness to Mechanical Stress and Biological Performance Following Cork Extract Functionalization
ACS Applied Bio Materials · 2025
DOI: 10.1021/acsabm.5c00449 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2025. Verfasst von Bruna A S Oliveira und 5 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Textile Science and Technology (2C2T), University of Minho, Campus of Azurém, 4800-058 Guimarães, Portugal. Hauptthemen laut MEDLINE: Plant Extracts, Biocompatible Materials, Anti-Bacterial Agents, Quercus. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Regional Development Fund, Funda??o para a Ci?ncia e a Tecnologia.
Abstract (Originalsprache)
Hand tendon ruptures have increased due to mechanical stress, degeneration, trauma, and repetitive motion. This study proposes an artificial tendon engineered from polymeric braids made of lyocell, biodegradable polyester, and polyethylene terephthalate, functionalized with natural cork extract. Cork extract 2, obtained by cork powder using hydroethanolic solvent in a planetary mixture, exhibited a phenolic content of 508.35 ± 82.26 mg GAE/g, flavonoid content of 607.32 ± 63.96 mg EQ/g, strong antioxidant activity (EC50 = 0.21 ± 0.02 mg/mL), and antimicrobial efficacy, with minimum bactericidal concentrations of 0.16 mg/mL against Staphylococcus aureus and 0.64 mg/mL against Pseudomonas aeruginosa. Single-polymer braids were processed with a core-shell structure, in which the core was formed of loose strands. The mechanical characterization of the braids showed the three polymers to exhibit an elongation at break of 8.72 ± 2.05-18.72 ± 6.58% and tensile strength of 44.22 ± 12.02-53.15 ± 12.62 MPa, all within desirable ranges for hand tendon repair/substitution. Braids were functionalized via physical adsorption of cork extract 2 (1.60 mg/mL), achieving loading values between 0.33 ± 0.16 and 0.55 ± 0.14 mg/mL. The presence of extract in the braids was confirmed via infrared spectroscopy and through thermal characterization, thermogravimetry, and differential scanning calorimetry. Functionalized braids exhibited controlled release of the cork extract 2, ranging from 1.57 ± 4.14 to 13.90 ± 2.02% within 24 h, ensuring sustained bioactivity, demonstrating as well strong antioxidant activity (87.42 ± 1.18 reduced 2,2-diphenyl-1-picrylhydrazyl), antimicrobial activity (achieving up to 99% reduction in S. aureus and 80% reduction in P. aeruginosa), and low cytotoxicity (>70% metabolic activity); with the functionalized lyocell presenting the best overall performance. In general, the proposed strategy demonstrated promise for hand tendon repair, offering a potential innovative solution to improve patients' quality of life.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Centre for Textile Science and Technology (2C2T), University of Minho, Campus of Azurém, 4800-058 Guimarães, Portugal.
- Centre of Biological Engineering (CEB), University of Minho, Campus of Gualtar, 4710-057 Braga, Portugal.
- LABBELS-Associate Laboratory, 4710-057 Braga, Guimarães, Portugal.
ORCID-Profile: Artur Ribeiro, Helena P Felgueiras
Förderung
- European Regional Development Fund
- Funda??o para a Ci?ncia e a Tecnologia
Zitieren
APA
Oliveira, B. A. S., Teixeira, M. O., Gonçalves, S. P., Ribeiro, A., Silva, C., & Felgueiras, H. P. (2025). Artificial Tendons’ Responsiveness to Mechanical Stress and Biological Performance Following Cork Extract Functionalization. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.5c00449
Vancouver
Oliveira BAS, Teixeira MO, Gonçalves SP, Ribeiro A, Silva C, Felgueiras HP. Artificial Tendons’ Responsiveness to Mechanical Stress and Biological Performance Following Cork Extract Functionalization. ACS Applied Bio Materials. 2025. doi:10.1021/acsabm.5c00449
BibTeX
@article{Oliveira2025,
author = {Oliveira, Bruna A S and Teixeira, Marta O and Gonçalves, Sónia P and Ribeiro, Artur and Silva, Carla and Felgueiras, Helena P},
title = {Artificial Tendons’ Responsiveness to Mechanical Stress and Biological Performance Following Cork Extract Functionalization},
journal = {ACS Applied Bio Materials},
year = {2025},
doi = {10.1021/acsabm.5c00449}
}
EUVIMED