Al 3+ -Responsive Ratiometric Fluorescent Sensor for Creatinine Detection: Thioflavin-T and Sulfated-β-Cyclodextrin Synergy
ACS Applied Bio Materials · 2023
DOI: 10.1021/acsabm.3c00349 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Applied Bio Materials, 2023. Verfasst von Sujata Bais und 1 weiteren Autor:innen. Beteiligte Einrichtung: Radiation & Photochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India. Hauptthemen laut MEDLINE: Sulfates, beta-Cyclodextrins. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 70 Literaturangaben. Gefördert von: Department of Atomic Energy, Government of India.
Abstract (Originalsprache)
Kidney disorders are a rising global health issue, necessitating early diagnosis for effective treatment. Creatinine, a metabolic waste product from muscles, serves as an ideal biomarker for kidney damage. The existing optical methods for creatinine detection often involve labor-intensive synthesis processes and present challenges with the aqueous solubility and sensitivity to experimental variations. In this study, we introduce a straightforward fluorescence "turn-on" ratiometric sensor system for creatinine detection in aqueous media with a limit of detection of 0.5 μM. The sensor is based on sulfated-β-cyclodextrin (SCD)-templated H-aggregate of a commercially available, ultrafast rotor dye thioflavin-T (ThT). The Al3+ ion-induced dissociation of ThT-SCD aggregates, followed by reassociation upon creatinine addition, generates a detectable signal. The modulation of monomer/aggregate equilibrium due to the disassembly/reassembly of the ThT-SCD system under Al3+/creatinine influence serves as the optimal strategy for ratiometric creatinine detection in aqueous media. Our sensor framework offers several advantages: utilization of the readily available dye ThT, which eliminates the need for a laborious synthesis of custom fluorescent probes; ratiometric sensing, which improves quantitative analysis accuracy; and compatibility with complex aqueous media. The sensor's practical utility has been successfully demonstrated in artificial urine samples. In summary, our sensor system represents a significant advancement in the rapid, selective, and sensitive detection of the clinically crucial bioanalyte creatinine, offering potential benefits for the early diagnosis and management of kidney disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiation & Photochemistry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India.
- Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai 400094, India.
ORCID-Profile: Prabhat K Singh
Förderung
- Department of Atomic Energy, Government of India
Zitieren
APA
Bais, S., & Singh, P. K. (2023). Al 3+ -Responsive Ratiometric Fluorescent Sensor for Creatinine Detection: Thioflavin-T and Sulfated-β-Cyclodextrin Synergy. ACS Applied Bio Materials. https://doi.org/10.1021/acsabm.3c00349
Vancouver
Bais S, Singh PK. Al 3+ -Responsive Ratiometric Fluorescent Sensor for Creatinine Detection: Thioflavin-T and Sulfated-β-Cyclodextrin Synergy. ACS Applied Bio Materials. 2023. doi:10.1021/acsabm.3c00349
BibTeX
@article{Bais2023,
author = {Bais, Sujata and Singh, Prabhat K},
title = {Al 3+ -Responsive Ratiometric Fluorescent Sensor for Creatinine Detection: Thioflavin-T and Sulfated-β-Cyclodextrin Synergy},
journal = {ACS Applied Bio Materials},
year = {2023},
doi = {10.1021/acsabm.3c00349}
}
EUVIMED