Remote Coacervate Robots with Visualized Bacteria Sensing and Removal in Indwelling Catheters for Infection Prevention
Nano Letters · 2026
DOI: 10.1021/acs.nanolett.6c04324 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nano Letters, 2026. Verfasst von Changshun Hou und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Medical Engineering, Beijing Institute of Technology, Zhuhai519088, P. R. China. Hauptthemen laut MEDLINE: Robotics, Urinary Tract Infections, Catheters, Indwelling, Catheter-Related Infections. Die Arbeit nennt 58 Literaturangaben. Gefördert von: Beijing Institute of Technology.
Themen: Nosokomiale Infektionen
Abstract (Originalsprache)
Catheter-associated urinary tract infections (CAUTIs) have been a common but challenging disease due to difficulties in the accurate prescribing of antibiotics, while existing clinical diagnostic methods are deficient in their quickness, simplicity, and convenience. Here we report a point-of-care sensing technique using untethered coacervate robots, which demonstrate high controllability and adaptation in confined catheters filled with viscous urine. Under different motion modes, the controlled coacervate robots can achieve a quick, visualized, and selective fluorescence response to Gram-negative bacteria from 102 CFU/mL to 107 CFU/mL in human urine as well as remove the colonized bacteria in the inner wall of catheters within 5 min. Blind tests on clinical urine samples with various bacterial infections reveal that the coacervate robots achieve 90% sensitivity and 100% specificity in identifying Gram-negative bacteriuria. The visualized sensing technique opens up a pathway for quick onsite diagnosis, which helps prevent infections associated with urinary catheters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Medical Engineering, Beijing Institute of Technology, Zhuhai519088, P. R. China.
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong999077, P. R. China.
ORCID-Profile: Changshun Hou
Förderung
- Beijing Institute of Technology
Zitieren
APA
Hou, C., Chen, Y., & Duan, X. (2026). Remote Coacervate Robots with Visualized Bacteria Sensing and Removal in Indwelling Catheters for Infection Prevention. Nano Letters. https://doi.org/10.1021/acs.nanolett.6c04324
Vancouver
Hou C, Chen Y, Duan X. Remote Coacervate Robots with Visualized Bacteria Sensing and Removal in Indwelling Catheters for Infection Prevention. Nano Letters. 2026. doi:10.1021/acs.nanolett.6c04324
BibTeX
@article{Hou2026,
author = {Hou, Changshun and Chen, Yichao and Duan, Xingguang},
title = {Remote Coacervate Robots with Visualized Bacteria Sensing and Removal in Indwelling Catheters for Infection Prevention},
journal = {Nano Letters},
year = {2026},
doi = {10.1021/acs.nanolett.6c04324}
}
EUVIMED