EUVIMEDEUVIMED entdecken
Crossref

Tracking Molecular Signatures at ppb Sensitivity Using Fluctuational Kinetics in Metal–Organic Frameworks

Balasubramanian Srinivasan iD, Arindam Phani iD, Xueliang Mu, Keekyoung Kim iD, Simon Park iD, Seonghwan Kim iD

Nano Letters · 14.05.2025 · 25 (19) · 7924-7932

DOI: 10.1021/acs.nanolett.5c01404 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nano Letters, online erschienen am 03.05.2025. Verfasst von Balasubramanian Srinivasan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Manufacturing Engineering, Schulich School of Engineering, University of Calgary, 2500 University Dr. NW, Calgary, Alber…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 54 Literaturangaben. Gefördert von: Canada Research Chairs, Natural Sciences and Engineering Research Council of Canada, Mitacs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biological systems achieve parts-per-billion (ppb) sensitivity in gas detection by tracking molecular fluctuations over time─a level of precision that remains difficult to replicate in engineered sensors. Conventional sensing relies on adsorption processes that require activation energies (Ea) ∼10 kBT, resulting in exponentially long equilibration times and limited selectivity due to small differences in Ea among analytes. Here, we show that volatile organics interacting with a ∼200 nm-thick nanoporous metal-organic framework (MOF), when subjected to shear-induced strain via a quartz crystal microbalance (QCM), exhibit a secondary fluctuational adsorption time scale distinct from the steady-state response. This emergent kinetic signature allows for reliable molecular discrimination at sensitivities down to ∼100 ppb. Our approach introduces a new selectivity metric based on dynamic adsorption kinetics, opening avenues for real-time molecular identification in environmental monitoring, portable diagnostics, and selective detection in chemically complex settings.

Schlagwörter

Stichwörter der Autor:innen

Adsorption kineticsAnomalous diffusionFluctuationsMOF sensorsMolecular speciationQCM sensorsToxic gas detection

Autor:innen und Institutionen

  • Department of Mechanical and Manufacturing Engineering, Schulich School of Engineering, University of Calgary, 2500 University Dr. NW, Calgary, Alberta T2N 1N4, Canada.
  • Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, 2500 University Dr. NW, Calgary, Alberta T2N 1N4, Canada.

ORCID-Profile: Balasubramanian Srinivasan, Arindam Phani, Keekyoung Kim, Simon Park, Seonghwan Kim

Förderung

  • Canada Research Chairs
  • Natural Sciences and Engineering Research Council of Canada
  • Mitacs

Zitieren

APA

Srinivasan, B., Phani, A., Mu, X., Kim, K., Park, S., & Kim, S. (2025). Tracking Molecular Signatures at ppb Sensitivity Using Fluctuational Kinetics in Metal–Organic Frameworks. Nano Letters, 25(19), 7924-7932. https://doi.org/10.1021/acs.nanolett.5c01404

Vancouver

Srinivasan B, Phani A, Mu X, Kim K, Park S, Kim S. Tracking Molecular Signatures at ppb Sensitivity Using Fluctuational Kinetics in Metal–Organic Frameworks. Nano Letters. 2025;25(19):7924-7932. doi:10.1021/acs.nanolett.5c01404

BibTeX
@article{Srinivasan2025,
  author = {Srinivasan, Balasubramanian and Phani, Arindam and Mu, Xueliang and Kim, Keekyoung and Park, Simon and Kim, Seonghwan},
  title = {Tracking Molecular Signatures at ppb Sensitivity Using Fluctuational Kinetics in Metal–Organic Frameworks},
  journal = {Nano Letters},
  year = {2025},
  volume = {25},
  number = {19},
  pages = {7924--7932},
  doi = {10.1021/acs.nanolett.5c01404}
}
Kostenlos starten →