Fachartikel in der Zeitschrift Nano Letters, 2025. Verfasst von Shuai Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR 999077, China. Hauptthemen laut MEDLINE: Muscular Atrophy, Wearable Electronic Devices, Biosensing Techniques, Wireless Technology. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, startup grant of CityU, contract research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring and evaluation of muscle atrophy are vital for efficient treatment and effective diagnosis. Although some systems have been developed to monitor loss of muscle mass or strength, they are bulky and nonspecific, cannot be applied to the body, and cannot assess the degree of muscle atrophy. Our research focuses on developing a wireless multisensor wearable system (WMWS) for on-body monitoring and assessment of atrophy, which utilizes a single-electrode triboelectric nanogenerator (S-TENG) and electrochemical creatinine (CREA) sensor to achieve real-time acquisition of plantar pressure and interstitial fluid (ISF) CREA concentration. In addition, LSTM (long short-term memory) and SVM (support vector machine) machine learning (ML) algorithms also prove that our multisensor strategy can effectively improve the recognition rate of different degrees of atrophy (the highest accuracy reached 92.32%). Overall, our work makes it possible to monitor and grade muscle atrophy remotely in real time.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscular AtrophyWearable Electronic DevicesBiosensing TechniquesWireless TechnologyHumansCreatinineSupport Vector MachineMonitoring, PhysiologicEquipment Design

Stichwörter der Autor:innen

creatinineflexible printed circuitmuscle atrophytriboelectric nanogenerator

Substanzen

Creatinine

Autor:innen und Institutionen

  • Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, SAR 999077, China.

ORCID-Profile: Chuanwei Zhi, Jinlian Hu

Förderung

  • National Natural Science Foundation of China
  • startup grant of CityU
  • contract research
  • Collaborative Research Fund

Zitieren

APA

Zhang, S., Meng, S., Tan, R., Zhang, K., Wang, Z., Xu, X., Zhi, C., Liang, X., & Hu, J. (2025). Wireless, Multisensor Integrated Bioelectronics for Real-Time Monitoring and Assessment of Muscle Atrophy. Nano Letters. https://doi.org/10.1021/acs.nanolett.4c05245

Vancouver

Zhang S, Meng S, Tan R, Zhang K, Wang Z, Xu X, et al. Wireless, Multisensor Integrated Bioelectronics for Real-Time Monitoring and Assessment of Muscle Atrophy. Nano Letters. 2025. doi:10.1021/acs.nanolett.4c05245

BibTeX
@article{Zhang2025,
  author = {Zhang, Shuai and Meng, Shuo and Tan, Renjie and Zhang, Ke and Wang, Zhuang and Xu, Xiaoyun and Zhi, Chuanwei and Liang, Xinshuo and Hu, Jinlian},
  title = {Wireless, Multisensor Integrated Bioelectronics for Real-Time Monitoring and Assessment of Muscle Atrophy},
  journal = {Nano Letters},
  year = {2025},
  doi = {10.1021/acs.nanolett.4c05245}
}
Kostenlos starten →