SnS 2 QDs@MXene Ohmic Junction-Based Surface Plasmon Coupling ECL Sensor to Detect Saliva Exosome for the Diagnosis of Childhood Asthma
Nano Letters · 2024
DOI: 10.1021/acs.nanolett.4c04939 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nano Letters, 2024. Verfasst von Zhenrun Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China. Hauptthemen laut MEDLINE: Asthma, Quantum Dots, Saliva, Sulfides. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
This study represents a novel surface plasmon coupling electrochemiluminescence (SPC-ECL) method for detecting salivary exosomes and the diagnosis of childhood asthma. First, SnS2 QDs@MXene Ohmic junctions was developed as efficient ECL emitters. The Ohmic junction provided a low resistance to reduce the contact resistance and improve charge injection efficiency, which enhanced the ECL signal by 2.76 times. Furthermore, the self-assembled surface plasmonic Bi@SiO2 array was prepared. When the ECL of SnS2 QDs@MXene resonated with the electronic oscillations in the Bi@SiO2 NPs array, the luminescence intensity was enhanced and regulated into the directionally polarized signal by the SPC-ECL effect. Remarkably, the detection of CD9-exosomes in saliva was achieved successfully based on the above sensing system, which can be used to analysis the acute exacerbation and chronic persistence of childhood asthma.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China.
ORCID-Profile: Qiang Ma
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Li, Z., Liang, Z., Wang, P., Li, W., Li, Y., Liu, N., & Ma, Q. (2024). SnS 2 QDs@MXene Ohmic Junction-Based Surface Plasmon Coupling ECL Sensor to Detect Saliva Exosome for the Diagnosis of Childhood Asthma. Nano Letters. https://doi.org/10.1021/acs.nanolett.4c04939
Vancouver
Li Z, Liang Z, Wang P, Li W, Li Y, Liu N, et al. SnS 2 QDs@MXene Ohmic Junction-Based Surface Plasmon Coupling ECL Sensor to Detect Saliva Exosome for the Diagnosis of Childhood Asthma. Nano Letters. 2024. doi:10.1021/acs.nanolett.4c04939
BibTeX
@article{Li2024,
author = {Li, Zhenrun and Liang, Zihui and Wang, Peilin and Li, Wenyan and Li, Yameng and Liu, Ning and Ma, Qiang},
title = {SnS 2 QDs@MXene Ohmic Junction-Based Surface Plasmon Coupling ECL Sensor to Detect Saliva Exosome for the Diagnosis of Childhood Asthma},
journal = {Nano Letters},
year = {2024},
doi = {10.1021/acs.nanolett.4c04939}
}
EUVIMED