Comparative Evaluation of Voxel-Level Dosimetry Methods in 90 Y-Microsphere Radioembolization Using PET/CT
Molecular Pharmaceutics · 2026
DOI: 10.1021/acs.molpharmaceut.5c01411 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Molecular Pharmaceutics, 2026. Verfasst von Hai Hu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal University, No. 19, Xinjiekouwai Street, Haidian District, Beiji…. Hauptthemen laut MEDLINE: Yttrium Radioisotopes, Radioembolization, Therapeutic, Positron Emission Tomography Computed Tomography, Liver Neoplasms. Die Arbeit nennt 38 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China.
Abstract (Originalsprache)
90Y-microsphere radioembolization is an established treatment for primary and metastatic liver cancer. Post-treatment PET/CT enables voxel-level absorbed dose estimation, but the optimal calculation method remains under evaluation. In this study, we compared three dosimetry approaches: Monte Carlo (MC), voxel S-value (VSV) method, and local energy deposition method (LDM). Post-treatment PET/CT data sets from 68 patients were analyzed (6 from the Deep Blue Data Repository and 62 from Beijing Tsinghua Changgung Hospital). MC dosimetry was implemented in GATE v9.0 and served as the reference standard. VSV was derived by convolving PET images with a precomputed 90Y voxel kernel, while LDM assumed complete local absorption of β-energy. Agreement with MC was assessed qualitatively using relative-difference maps, dose profiles, and isodose overlays, and quantitatively via voxelwise root-mean-square error (RMSE), Pearson correlation, Bland-Altman analysis of mean absorbed dose and equivalent uniform biological effective dose (EUBED), and absolute maximum deviations between cumulative and differential dose-volume histograms (DVHs) (1 Gy bins). MC simulations required ∼41 h per case, whereas the VSV kernel calculation required only one simulation with ∼6 h. Then VSV and LDM costed only a few seconds to obtain the dose images. VSV preserved MC isodose geometry and dose-profile shapes, while LDM overestimated doses in high-dose regions. At profile maxima, VSV's peak relative deviation was ∼1-3% versus ∼12-19% for LDM. Across patients, VSV achieved a voxelwise RMSE of 2.21% and
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Advanced Quantum Studies, School of Physics and Astronomy, Beijing Normal University, No. 19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
- Key Laboratory of Multiscale Spin Physics (Ministry of Education), Beijing Normal University, No. 19, Xinjiekouwai Street, Haidian District, Beijing 100875, China.
- Laboratory of Soft Matter Physics, Institute of Physics, Chinese Academy of Sciences, No. 8, South Third Street, Zhongguancun, Haidian District, Beijing 100190, China.
- University of Chinese Academy of Sciences, No. 80, Zhongguancun East Road, Haidian District, Beijing 100190, China.
- Department of Nuclear Medicine, Beijing Tsinghua Changgung Hospital, No. 168, Litang Road, Changping District, Beijing 102218, China.
- Department of Engineering Physics, Tsinghua University, Haidian District, Tsinghua Campus, Beijing 100084, China.
Förderung
- National Key Research and Development Program of China
- Natural Science Foundation of Beijing Municipality
- National Natural Science Foundation of China
- CIRP Open Fund of Radiation Protection Laboratories
Zitieren
APA
Hu, H., Liang, Z. W., Zhao, Y. B., Liu, H., Dai, T. T., Wei, Q. Y., Jiao, F., Hang, Z. B., Liu, Y. Q., He, Z. X., & Wu, J. (2026). Comparative Evaluation of Voxel-Level Dosimetry Methods in 90 Y-Microsphere Radioembolization Using PET/CT. Molecular Pharmaceutics. https://doi.org/10.1021/acs.molpharmaceut.5c01411
Vancouver
Hu H, Liang ZW, Zhao YB, Liu H, Dai TT, Wei QY, et al. Comparative Evaluation of Voxel-Level Dosimetry Methods in 90 Y-Microsphere Radioembolization Using PET/CT. Molecular Pharmaceutics. 2026. doi:10.1021/acs.molpharmaceut.5c01411
BibTeX
@article{Hu2026,
author = {Hu, Hai and Liang, Zi-Wei and Zhao, Ya-Bo and Liu, Hui and Dai, Tian-Tian and Wei, Qing-Yang and Jiao, Fang and Hang, Zhong-Bin and Liu, Ya-Qiang and He, Zuo-Xiang and Wu, Jing},
title = {Comparative Evaluation of Voxel-Level Dosimetry Methods in 90 Y-Microsphere Radioembolization Using PET/CT},
journal = {Molecular Pharmaceutics},
year = {2026},
doi = {10.1021/acs.molpharmaceut.5c01411}
}
EUVIMED