Abstract (Originalsprache)

Flexible capacitive tactile sensors are essential components for emerging human-machine interfaces, electronic skins, and wearable healthcare systems. However, the weak pressure-induced modulation of the electrode-dielectric interface in conventional planar configurations can limit the capacitance variation generated by small mechanical stimuli. Here, we develop a highly sensitive capacitive tactile sensor based on copper nanocone electrodes that regulate the local electric-field distribution and the pressure-dependent interfacial geometry. The nanocone arrays are fabricated through a two-electrode electrodeposition strategy, and their height and array density are systematically regulated to examine how electrode geometry affects field redistribution and pressure-induced interfacial capacitance variation. Finite element simulations reveal geometry-dependent stress and electric-field redistribution, while the measured structure-performance relationships indicate that nanocone geometry influences capacitive sensing through coupled electrical and interfacial effects. The optimized sensor achieves a sensitivity of 6.29 kPa–1 over 0–20 kPa, a minimum detectable load of 200 mg, a response time of 99 ms, and stable operation over 15,000 loading–unloading cycles. Airflow-pulse encoding of Morse signals demonstrates the detection of weak airflow-induced pressure changes without solid contact. This work provides a geometry-engineering strategy for jointly regulating the electric-field distribution and pressure-dependent contact state at electrode-dielectric interfaces.

Förderung

  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Chinese Academy of Sciences
  • Jiangsu Funding Program for Excellent Postdoctoral Talent

Zitieren

APA

Lyu, P., Zhang, Z., Xu, W., Gong, L., Ye, Z., Chen, Q., Yang, L., Zhou, Q., & Pan, G. (2026). Copper Nanocone Electrodes for Capacitive Pressure Sensing through Electric-Field Redistribution and Interfacial Modulation. Langmuir. https://doi.org/10.1021/acs.langmuir.6c04815

Vancouver

Lyu P, Zhang Z, Xu W, Gong L, Ye Z, Chen Q, et al. Copper Nanocone Electrodes for Capacitive Pressure Sensing through Electric-Field Redistribution and Interfacial Modulation. Langmuir. 2026. doi:10.1021/acs.langmuir.6c04815

BibTeX
@article{Lyu2026,
  author = {Lyu, Peiyu and Zhang, Ziang and Xu, Wenqing and Gong, Lin and Ye, Zhiqiu and Chen, Qin and Yang, Limei and Zhou, Quan and Pan, Gebo},
  title = {Copper Nanocone Electrodes for Capacitive Pressure Sensing through Electric-Field Redistribution and Interfacial Modulation},
  journal = {Langmuir},
  year = {2026},
  doi = {10.1021/acs.langmuir.6c04815}
}
Kostenlos starten →