EUVIMEDEUVIMED entdecken
Crossref

A Au/Cu-COF Membrane-Based SERS Sensor for Noninvasive Detection of Helicobacter pylori via Exhaled Breath Ammonia

Wenjing Zhao, Guangxi Li, Mingwan Su, Pengfei An iD, Xiaoyan Yao, Shengbin Lei iD, Caihong Tao, Min Li iD

Langmuir · 16.06.2026 · 42 (23) · 17099-17108

DOI: 10.1021/acs.langmuir.6c02130 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, online erschienen am 04.06.2026. Verfasst von Wenjing Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China. Hauptthemen laut MEDLINE: Helicobacter pylori, Gold, Copper, Ammonia. Die Arbeit nennt 33 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A surface-enhanced Raman scattering (SERS) sensor built on a free-standing Au/Cu-covalent organic framework (COF) membrane was developed for the noninvasive Helicobacter pylori detection by quantifying trace ammonia in exhaled breath. The porphyrin-based Cu-COF acts as a multifunctional sensing interface, using its porous structure and accessible porphyrin-Cu coordination sites to efficiently capture and preconcentrate ammonia vapor. The change of intensity of the characteristic SERS peak at the 391 cm–1 Raman peak (ΔI391) shows a good linear relationship with ammonia concentration in the range of 0.5 to 3 ppm, with a limit of detection (LOD) down to 0.5 ppm. The sensor shows good stability and anti-interference ability toward common volatile organic compounds (VOCs) and inorganic gases in breath, allowing rapid detection without complex sample pretreatment. Notably, the introduction of Cu2+ significantly enhanced the crystallinity and structure ordering of the COF membrane, offering a new strategy for metal-ion-mediated structural regulation of 2D COF films. Preliminary clinical blind testing on exhaled breath samples yields a 70% diagnostic accuracy for H. pylori infection, validating the practical potential of this sensor. This work establishes a robust SERS platform for breath biomarker analysis and provides a promising route for noninvasive, real-time, and point-of-care diagnosis of H. pylori infection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Helicobacter pyloriGoldCopperAmmoniaMetal-Organic FrameworksSpectrum Analysis, RamanBreath TestsHumansSurface PropertiesMembranes, ArtificialLimit of Detection

Substanzen

GoldCopperAmmoniaMetal-Organic FrameworksMembranes, Artificial

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Lanzhou Jiaotong University, Lanzhou 730070, China.
  • CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • Respiratory Department, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Beijing 100053, China.
  • Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China.
  • State Key Laboratory of Advanced Materials for Intelligent Sensing, Key Laboratory of Organic Integrated Circuits, Ministry of Education & Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemi…

ORCID-Profile: Pengfei An, Shengbin Lei, Min Li

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Zhao, W., Li, G., Su, M., An, P., Yao, X., Lei, S., Tao, C., & Li, M. (2026). A Au/Cu-COF Membrane-Based SERS Sensor for Noninvasive Detection of Helicobacter pylori via Exhaled Breath Ammonia. Langmuir, 42(23), 17099-17108. https://doi.org/10.1021/acs.langmuir.6c02130

Vancouver

Zhao W, Li G, Su M, An P, Yao X, Lei S, et al. A Au/Cu-COF Membrane-Based SERS Sensor for Noninvasive Detection of Helicobacter pylori via Exhaled Breath Ammonia. Langmuir. 2026;42(23):17099-17108. doi:10.1021/acs.langmuir.6c02130

BibTeX
@article{Zhao2026,
  author = {Zhao, Wenjing and Li, Guangxi and Su, Mingwan and An, Pengfei and Yao, Xiaoyan and Lei, Shengbin and Tao, Caihong and Li, Min},
  title = {A Au/Cu-COF Membrane-Based SERS Sensor for Noninvasive Detection of Helicobacter pylori via Exhaled Breath Ammonia},
  journal = {Langmuir},
  year = {2026},
  volume = {42},
  number = {23},
  pages = {17099--17108},
  doi = {10.1021/acs.langmuir.6c02130}
}
Kostenlos starten →