EUVIMEDEUVIMED entdecken
Crossref

Fluorescence Regulation of N,P-CQDs and Their Application in Cr 3+ Ion Detection

Jingmei Lu, Jikun Shen, Meng Zhang, Na Zheng, Zhaoyu Ma, Yunxia Jin, Ju Tang, Fan Zhang, Guo Chen iD

Langmuir · 19.05.2026 · 42 (19) · 13402-13413

DOI: 10.1021/acs.langmuir.6c00228 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, online erschienen am 06.05.2026. Verfasst von Jingmei Lu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Kunming Key Laboratory of Energy Materials Chemistry, Yunnan Minzu University, Kunming 650500, Yunnan, P. R. China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Yunnan Provincial Science and Technology Department.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the key issues of traditional carbon quantum dots (CQDs), such as unstable photophysical and photochemical properties and limited carrier transport performance, N,P-CQDs were prepared via a one-step hydrothermal synthesis method in this study. By regulating the mass ratio of carbon-to-nitrogen sources, we systematically explored the fluorescence properties of four N,P-CQDs. The findings demonstrated that N,P-CQDs-2 prepared at 180 °C for 8 h with a citric acid-to-ammonium dihydrogen phosphate molar ratio of 1.15:1.0 exhibited the optimal optical performance. The material showed excellent stability with 76.96% fluorescence retention after 180 days of storage at room temperature and stable fluorescence in pH 1-13, demonstrating favorable acid-base resistance. Structure, morphology, and optical properties were characterized by X-ray powder diffractometer (XRD), Fourier transform infrared spectrometer (FT-IR), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM), fluorescence spectrophotometer (PL), ultraviolet-visible (UV-vis), and steady-state/transient fluorescence spectrometer (FLS). All samples emitted blue fluorescence under UV light. The carbon-nitrogen ratio did not change the core structure but obviously affected fluorescence intensity and emission peaks. N,P-CQDs-2 was used as a fluorescent probe for ion detection. After different metal ions (Ni2+, Fe2+, Cu2+, Mg2+, Cr3+) were added to its aqueous solution, the system's fluorescence emission intensity showed differential attenuation. Among them, the fluorescence quenching effect induced by Cr3+ was the most significant. The fluorescence quenching efficiency of N,P-CQDs-2 shows a good linear relationship with the concentration of Cr3+ in the range of 150-330 μg/mL, with a correlation coefficient R2 of 0.977 and a limit of detection as low as 0.25 mg/L. Based on the characterization results of FT-IR, UV-vis absorption, and fluorescence lifetime, the fluorescence quenching process is verified to be dominated by the static quenching mechanism. This green and low-cost method provides a valuable reference for efficient Cr3+ detection.

Autor:innen und Institutionen

  • Kunming Key Laboratory of Energy Materials Chemistry, Yunnan Minzu University, Kunming 650500, Yunnan, P. R. China.

ORCID-Profile: Guo Chen

Förderung

  • Yunnan Provincial Science and Technology Department

Zitieren

APA

Lu, J., Shen, J., Zhang, M., Zheng, N., Ma, Z., Jin, Y., Tang, J., Zhang, F., & Chen, G. (2026). Fluorescence Regulation of N,P-CQDs and Their Application in Cr 3+ Ion Detection. Langmuir, 42(19), 13402-13413. https://doi.org/10.1021/acs.langmuir.6c00228

Vancouver

Lu J, Shen J, Zhang M, Zheng N, Ma Z, Jin Y, et al. Fluorescence Regulation of N,P-CQDs and Their Application in Cr 3+ Ion Detection. Langmuir. 2026;42(19):13402-13413. doi:10.1021/acs.langmuir.6c00228

BibTeX
@article{Lu2026,
  author = {Lu, Jingmei and Shen, Jikun and Zhang, Meng and Zheng, Na and Ma, Zhaoyu and Jin, Yunxia and Tang, Ju and Zhang, Fan and Chen, Guo},
  title = {Fluorescence Regulation of N,P-CQDs and Their Application in Cr 3+ Ion Detection},
  journal = {Langmuir},
  year = {2026},
  volume = {42},
  number = {19},
  pages = {13402--13413},
  doi = {10.1021/acs.langmuir.6c00228}
}
Kostenlos starten →