Nanostructured Bismuth-Doped Cobalt Ferrite (Bi x CoFe 2 O 4 ) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring
Langmuir · 2025
DOI: 10.1021/acs.langmuir.5c01951 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, 2025. Verfasst von Siddhima Singh und 4 weiteren Autor:innen. Beteiligte Einrichtung: Sam Higginbottom University of Agriculture, Technology and Sciences, Prayagraj 211007, Uttar Pradesh, India. Hauptthemen laut MEDLINE: Cobalt, C-Reactive Protein, Bismuth, Ferric Compounds. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: Banaras Hindu University.
Abstract (Originalsprache)
Globally, cardiovascular disease (CVD) constitute a primary source of morbidity and mortality. Timely and precise diagnosis of pertinent biomarkers and function parameters can provide valuable insight into the physiological and pathological processes associated with CVD. This research aims to develop a new sensing platform for C-reactive protein (CRP) to detect cardiovascular disease, utilizing an indium tin oxide (ITO) electrode modified with hydrothermally synthesized bismuth-doped cobalt ferrite (BixCoFe2O4) nanoparticles (NPs) by varying bismuth concentrations of (x = 0.5, 0.10, 0.15, 0.20 M). These synthesized doped NPs are characterized by using XRD, FTIR, UV, scanning electron microscopy (SEM), HR-TEM, energy-dispersive X-ray (EDX), dynamic light scattering (DLS), and AFM techniques to ascertain their morphological and structural properties. The modified material was deposited on the ITO electrode via the electrophoretic deposition (EPD) method. The electrochemical study indicates that the modified electrode exhibits a higher current density than the bare ITO electrode. CRP immobilization was performed by the drop casting method, and the electrochemical impedance spectroscopy (EIS) demonstrates that the developed immunoelectrode exhibits a linear concentration at a lower range from 0.5 to 100 ng/mL and a higher range of 100-500 ng/mL. The sensitivity has been observed at 0.376305 and 0.05492 Ω/ng cm2, with the limit of detection (LOD) of 0.15 and 0.22 ng/mL, the limit of quantification (LOQ) of 0.51 and 0.74 ng/mL, and the response time of 20 s. The study is significant in the field of CVD, as it assesses inflammation and cardiovascular risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Sam Higginbottom University of Agriculture, Technology and Sciences, Prayagraj 211007, Uttar Pradesh, India.
- Department of Chemistry, Institute of Sciences, Banaras Hindu University, Varanasi 221005, Uttar Pradesh, India.
ORCID-Profile: Jay Singh
Förderung
- Banaras Hindu University
Zitieren
APA
Singh, S., Singh, A., Shaktawat, S., Singh, N., & Singh, J. (2025). Nanostructured Bismuth-Doped Cobalt Ferrite (Bi x CoFe 2 O 4 ) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring. Langmuir. https://doi.org/10.1021/acs.langmuir.5c01951
Vancouver
Singh S, Singh A, Shaktawat S, Singh N, Singh J. Nanostructured Bismuth-Doped Cobalt Ferrite (Bi x CoFe 2 O 4 ) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring. Langmuir. 2025. doi:10.1021/acs.langmuir.5c01951
BibTeX
@article{Singh2025,
author = {Singh, Siddhima and Singh, Astha and Shaktawat, Sarita and Singh, Neelottma and Singh, Jay},
title = {Nanostructured Bismuth-Doped Cobalt Ferrite (Bi x CoFe 2 O 4 ) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring},
journal = {Langmuir},
year = {2025},
doi = {10.1021/acs.langmuir.5c01951}
}
EUVIMED