EUVIMEDEUVIMED entdecken
Crossref

Two-Photon Probe Executes the Restrained-Vibration Mechanism for Pathological Viscosity Detection In Vivo

Zizi Wu, Mingxuan Jia, Han Yu, Weiqian Zhang, Weiqing Yue, Wenbo Hu iD, Xiaomei Lu, Zhijie Fang, Jie Li iD, Wei Huang

Langmuir · 2025

DOI: 10.1021/acs.langmuir.5c01719 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2025. Verfasst von Zizi Wu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM) and School of Flexible Electronics (Future Technologies), Nanj…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Photons. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The fluorescence efficiency is closely linked to the vibration relaxation process. In high-viscosity conditions, the vibration relaxation process is restricted, significantly enhancing fluorescence intensity. Based on this principle, we successfully designed and synthesized a viscosity-sensitive two-photon fluorescent probe, DCM1. Through density functional theory calculations, we elucidated the molecular conformational changes and the regulation of energy dissipation mechanisms under high-viscosity conditions. In glycerol solution, the fluorescence intensity of DCM1 is 36 times higher than that in aqueous solution, demonstrating its high sensitivity to microenvironmental viscosity changes. Furthermore, DCM1 exhibits excellent optical properties under two-photon excitation. At an excitation wavelength of 1000 nm, the two-photon absorption cross section reaches 181 GM. Leveraging these characteristics, DCM1 was successfully applied in two-photon fluorescence imaging experiments with live zebrafish, achieving high-resolution deep-tissue fluorescence imaging with a maximum penetration depth of 154 μm. This result demonstrates that the DCM1 probe can not only sensitively respond to viscosity changes in biological systems but also achieve deep-tissue fluorescence imaging, providing a novel tool for the diagnosis and mechanistic study of high-viscosity-related disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesPhotonsViscosityAnimalsZebrafishOptical ImagingVibrationDensity Functional Theory

Substanzen

Fluorescent Dyes

Autor:innen und Institutionen

  • Key Laboratory of Flexible Electronics (KLOFE) & Institute of Advanced Materials (IAM) and School of Flexible Electronics (Future Technologies), Nanjing Tech University (Nanjing Tech), Nanjing 211800, China.
  • Frontiers Science Center for Flexible Electronics Xi'an Institute of Flexible Electronics (IFE), Northwestern Polytechnical University, Xian 710072, China.

ORCID-Profile: Wenbo Hu, Jie Li

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wu, Z., Jia, M., Yu, H., Zhang, W., Yue, W., Hu, W., Lu, X., Fang, Z., Li, J., & Huang, W. (2025). Two-Photon Probe Executes the Restrained-Vibration Mechanism for Pathological Viscosity Detection In Vivo. Langmuir. https://doi.org/10.1021/acs.langmuir.5c01719

Vancouver

Wu Z, Jia M, Yu H, Zhang W, Yue W, Hu W, et al. Two-Photon Probe Executes the Restrained-Vibration Mechanism for Pathological Viscosity Detection In Vivo. Langmuir. 2025. doi:10.1021/acs.langmuir.5c01719

BibTeX
@article{Wu2025,
  author = {Wu, Zizi and Jia, Mingxuan and Yu, Han and Zhang, Weiqian and Yue, Weiqing and Hu, Wenbo and Lu, Xiaomei and Fang, Zhijie and Li, Jie and Huang, Wei},
  title = {Two-Photon Probe Executes the Restrained-Vibration Mechanism for Pathological Viscosity Detection In Vivo},
  journal = {Langmuir},
  year = {2025},
  doi = {10.1021/acs.langmuir.5c01719}
}
Kostenlos starten →