Optical and Acoustic Characterization of Phase-Shift Droplets with Varying Shell Compositions
Langmuir · 18.03.2025 · 41 (10) · 6816-6830
DOI: 10.1021/acs.langmuir.4c05030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 05.03.2025. Verfasst von Sugandha Chaudhary und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States. Hauptthemen laut MEDLINE: Fluorocarbons, Acoustics. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, University of Michigan, National Heart, Lung, and Blood Institute.
Abstract (Originalsprache)
Shell-stabilized, phase-shift droplets of perfluorocarbon have shown promising potential in diagnostic and therapeutic ultrasound applications. While the role of shell composition has been well-studied for conventional gas-filled microbubbles, its influence on bubbles generated via acoustic droplet vaporization (ADV) remains understudied. This study investigates the effect of shell composition─lipid, protein, and polymer─on the stability, ADV dynamics, growth behavior, release kinetics, and acoustic response of perfluorohexane phase-shift droplets. Payload-carrying, micron-sized droplets were produced using a microfluidic platform. Both optical, including ultrahigh-speed and timelapse confocal microscopy, and acoustic characterizations of the generated droplets were investigated in fibrin-based, tissue-mimicking hydrogels. Fluorescent markers were used to selectively label fibrin, payload, and droplet shells. Following insonation at 2.5 and 9.6 MHz, lipid-coated droplets had a maximum expansion ratio up to 20% lower than protein- and polymer-coated droplets. Payload release rates were an order of magnitude faster than the bubble growth rate post ADV, with minimal dependence on shell composition. Additionally, lipid shell fluorescence retained up to 40% of its initial intensity 120 s after ADV, while protein shell fluorescence was completely diminished. Acoustic characterization indicated that the ADV and inertial cavitation thresholds were similar across all shell types, suggesting that shell composition has a negligible effect on acoustic characteristics at high driving pressures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
- Applied Physics Program, University of Michigan, Ann Arbor, Michigan 48109-5667, United States.
ORCID-Profile: Bachir A Abeid, Mario L Fabiilli, Mitra Aliabouzar
Förderung
- NHLBI NIH HHS
- University of Michigan
- National Heart, Lung, and Blood Institute
- Research Scouts Program
Zitieren
APA
Chaudhary, S., Kaushik, A., Abeid, B. A., Estrada, J. B., Fabiilli, M. L., & Aliabouzar, M. (2025). Optical and Acoustic Characterization of Phase-Shift Droplets with Varying Shell Compositions. Langmuir, 41(10), 6816-6830. https://doi.org/10.1021/acs.langmuir.4c05030
Vancouver
Chaudhary S, Kaushik A, Abeid BA, Estrada JB, Fabiilli ML, Aliabouzar M. Optical and Acoustic Characterization of Phase-Shift Droplets with Varying Shell Compositions. Langmuir. 2025;41(10):6816-6830. doi:10.1021/acs.langmuir.4c05030
BibTeX
@article{Chaudhary2025,
author = {Chaudhary, Sugandha and Kaushik, Anuj and Abeid, Bachir A and Estrada, Jonathan B and Fabiilli, Mario L and Aliabouzar, Mitra},
title = {Optical and Acoustic Characterization of Phase-Shift Droplets with Varying Shell Compositions},
journal = {Langmuir},
year = {2025},
volume = {41},
number = {10},
pages = {6816--6830},
doi = {10.1021/acs.langmuir.4c05030}
}
EUVIMED