Enhanced Flotation for the Removal of Pharmaceutical Contaminants from Water Systems Using Graphene Oxide–CTAB Nanocomposites
Langmuir · 2025
DOI: 10.1021/acs.langmuir.4c04066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, 2025. Verfasst von Gowri Pooja und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam 603 110, Tamil Nadu, India. Hauptthemen laut MEDLINE: Graphite, Water Pollutants, Chemical, Nanocomposites, Ibuprofen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 66 Literaturangaben.
Abstract (Originalsprache)
This study investigates the removal of pharmaceutical contaminants ibuprofen and diclofenac from aqueous solutions using graphene oxide (GO) coated with cetyltrimethylammonium bromide (CTAB) as a nanocomposite in a fully pressurized dissolved air flotation process. This novel approach leverages the surface-active properties of GO-CTAB to efficiently eliminate pharmaceuticals under optimized conditions. Characterization techniques, including Fourier transform infrared (FTIR), ζ-potential, particle size analysis, surface tension measurements, contact angle assessment, Brunauer-Emmett-Teller (BET) analysis, Gas chromatography-mass spectrometry (GC-MS), and Field emission scanning electron microscopy (FE-SEM) Energy-dispersive X-ray spectroscopy (EDS), validated the successful synthesis and efficacy of the GO-CTAB nanocomposite in pollutant removal. The process parameters were optimized, with the highest removal efficiencies achieved at a pH of 5 for ibuprofen and pH 4 for diclofenac, a surfactant dosage of 0.4 g, a pressure of 15 psig, and a rate of flow of 0.5 L/min. Under these conditions, removal efficiencies of 99.29% for ibuprofen and 95.31% for diclofenac were obtained, demonstrating the high performance of the GO-CTAB nanocomposite in treating low-concentration pharmaceutical contaminants. This study underscores the potential of the GO-CTAB flotation process as a sustainable, eco-friendly, and highly effective solution for pharmaceutical wastewater treatment, offering sustainability while minimizing chemical usage and environmental impact.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam 603 110, Tamil Nadu, India.
- Centre of Excellence in Water Research (CEWAR), Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam 603 110, Tamil Nadu, India.
- Centre for Pollution Control and Environmental Engineering, School of Engineering and Technology, Pondicherry University, Kalapet, Puducherry 605014, India.
- Department of Civil Engineering, Faculty of Engineering, Karpagam Academy of Higher Education, Pollachi Main Road, Eachanari Post, Coimbatore 641021, Tamil Nadu, India.
ORCID-Profile: Ponnusamy Senthil Kumar, Chitra Boobalan, Gayathri Rangasamy
Zitieren
APA
Pooja, G., Senthil Kumar, P., Boobalan, C., & Rangasamy, G. (2025). Enhanced Flotation for the Removal of Pharmaceutical Contaminants from Water Systems Using Graphene Oxide–CTAB Nanocomposites. Langmuir. https://doi.org/10.1021/acs.langmuir.4c04066
Vancouver
Pooja G, Senthil Kumar P, Boobalan C, Rangasamy G. Enhanced Flotation for the Removal of Pharmaceutical Contaminants from Water Systems Using Graphene Oxide–CTAB Nanocomposites. Langmuir. 2025. doi:10.1021/acs.langmuir.4c04066
BibTeX
@article{Pooja2025,
author = {Pooja, Gowri and Senthil Kumar, Ponnusamy and Boobalan, Chitra and Rangasamy, Gayathri},
title = {Enhanced Flotation for the Removal of Pharmaceutical Contaminants from Water Systems Using Graphene Oxide–CTAB Nanocomposites},
journal = {Langmuir},
year = {2025},
doi = {10.1021/acs.langmuir.4c04066}
}
EUVIMED