Synergistic Effect of Nickel Hydroxide/Hexagonal Boron Nitride Hybrid: An Efficient Electrocatalyst for Detecting 5-Fluorouracil in Human Blood Serum
Langmuir · 21.01.2025 · 41 (2) · 1321-1332
DOI: 10.1021/acs.langmuir.4c03868 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 07.01.2025. Verfasst von Magesh Kumar Muthukumaran und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu India. Hauptthemen laut MEDLINE: Fluorouracil, Nickel, Boron Compounds, Electrochemical Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: SRM Institute of Science and Technology.
Abstract (Originalsprache)
5-Fluorouracil (5-Fu) is the third-most often used chemotherapeutic medication and has been scientifically demonstrated to be effective in treating solid tumors, including colorectal, stomach, cutaneous, and breast cancers. When used in excess, it accumulates toxic metabolites, which can have deadly and very harmful effects on people, including neurotoxicity and the induction of morbidity. Therefore, sensitive and rapid analytical techniques for detecting 5-Fu in human blood serum are needed to enhance chemotherapy and forecast the possible adverse effects of 5-Fu residues in the human body. In this report, we developed a simple preparation of three-dimensional/two-dimensional (3D/2D) Nickel hydroxide/hexagonal boron nitride modified with a glassy carbon electrode [Ni(OH)2/h-BN/GCE] for effective electrochemical detection of the 5-fluorouracil with high selectivity. The X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), high-resolution scanning electron microscopy (HR-SEM), and HR-Transmission electron microscopy (HR-TEM) were used to characterize the crystalline, structural, and chemical properties of the as-synthesized materials. Moreover, the cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), square wave voltammetry (SWV), and i-t curves examined the electrode's electrochemical properties and sensor applications. Therefore, under ideal circumstances, Ni(OH)2/h-BN/GCE demonstrated outstanding 5-Fu selectivity, durability, a low LOD (0.001 μM), and a good linear range (0.02-12 μM). Finally, excellent results were obtained while testing this sensor for 5-Fu sensing in human blood serum.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu India.
ORCID-Profile: Magesh Kumar Muthukumaran, Muthukumar Govindaraj, Arockia Selvi J
Förderung
- SRM Institute of Science and Technology
Zitieren
APA
Muthukumaran, M. K., Govindaraj, M., & J, A. S. (2025). Synergistic Effect of Nickel Hydroxide/Hexagonal Boron Nitride Hybrid: An Efficient Electrocatalyst for Detecting 5-Fluorouracil in Human Blood Serum. Langmuir, 41(2), 1321-1332. https://doi.org/10.1021/acs.langmuir.4c03868
Vancouver
Muthukumaran MK, Govindaraj M, J AS. Synergistic Effect of Nickel Hydroxide/Hexagonal Boron Nitride Hybrid: An Efficient Electrocatalyst for Detecting 5-Fluorouracil in Human Blood Serum. Langmuir. 2025;41(2):1321-1332. doi:10.1021/acs.langmuir.4c03868
BibTeX
@article{Muthukumaran2025,
author = {Muthukumaran, Magesh Kumar and Govindaraj, Muthukumar and J, Arockia Selvi},
title = {Synergistic Effect of Nickel Hydroxide/Hexagonal Boron Nitride Hybrid: An Efficient Electrocatalyst for Detecting 5-Fluorouracil in Human Blood Serum},
journal = {Langmuir},
year = {2025},
volume = {41},
number = {2},
pages = {1321--1332},
doi = {10.1021/acs.langmuir.4c03868}
}