EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fabrication of Nanobioengineered Interfaces Utilizing Quaternary Nanocomposite for Highly Efficient and Selective Electrochemical Biosensing of Urea

Krishna Kumar, Kshitij Rb Singh, Ritu S Rathour, Jay Singh iD, Subrato Bhattacharya iD, Shyam S Pandey iD

Langmuir · 2024

DOI: 10.1021/acs.langmuir.4c02457 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2024. Verfasst von Krishna Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Urea, Nanocomposites, Urease. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nanobioengineered interfaces have gained attention owing to their small size and high surface area-to-volume ratio for utilization as a platform for highly selective and sensitive biosensing applications owing to the integration of biological molecules with engineered nanomaterials/nanocomposites. In this work, a novel Ag-complex, [(PPh3)2Ag(SCOf)]-based quaternary Ag-S-Zn-O nanocomposites (NCs), was synthesized through an environmentally-friendly process. The results revealed the formation of the NCs with an average crystallite size and particle size of 36.08 and 40.22 nm, respectively. In addition, this is the first study to utilize such NCs synthesized via a single-source precursor method, offering enhanced sensor performance due to their unique structural properties. Further, these NCs were used to fabricate a urease (Ur)/Ag-S-Zn-O NCs/ITO nanobioengineered electrode for precise and sensitive electrochemical biosensing of urea. The interfacial kinetic studies revealed quasi-reversible processes with high electron transfer rates and linear current responses, indicating efficient reaction dynamics. A high diffusion coefficient and low surface concentration suggested a fast diffusion-controlled process, affirming the electrode's potential for rapid and sensitive urea detection. The biosensor demonstrated notable sensing properties such as high sensitivity (12.56 μA mM-1 cm-2) and a low detection limit (0.54 mM). The fabricated bioelectrode was highly selective and reproducible and demonstrated stability for up to 60 days. These results validate the potential of this nanobioengineered interface for next-generation biosensing applications, paving the way for advanced point-of-care diagnostics and real-time health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesUreaNanocompositesUreaseElectrochemical TechniquesSilverParticle SizeZinc OxideElectrodesSurface Properties

Substanzen

UreaUreaseSilverZinc Oxide

Autor:innen und Institutionen

  • Department of Chemistry, Institute of Science, Banaras Hindu University, Varanasi 221005, India.
  • Graduate School of Life Science and Systems Engineering, Kyushu Institute of Technology, 2-4 Hibikino, Wakamatsu, Kitakyushu 808-0196, Japan.
  • Department of Chemistry, School of Applied Sciences, Amity University, Lucknow 226028, India.

ORCID-Profile: Jay Singh, Subrato Bhattacharya, Shyam S Pandey

Zitieren

APA

Kumar, K., Singh, K. R., Rathour, R. S., Singh, J., Bhattacharya, S., & Pandey, S. S. (2024). Fabrication of Nanobioengineered Interfaces Utilizing Quaternary Nanocomposite for Highly Efficient and Selective Electrochemical Biosensing of Urea. Langmuir. https://doi.org/10.1021/acs.langmuir.4c02457

Vancouver

Kumar K, Singh KR, Rathour RS, Singh J, Bhattacharya S, Pandey SS. Fabrication of Nanobioengineered Interfaces Utilizing Quaternary Nanocomposite for Highly Efficient and Selective Electrochemical Biosensing of Urea. Langmuir. 2024. doi:10.1021/acs.langmuir.4c02457

BibTeX
@article{Kumar2024,
  author = {Kumar, Krishna and Singh, Kshitij Rb and Rathour, Ritu S and Singh, Jay and Bhattacharya, Subrato and Pandey, Shyam S},
  title = {Fabrication of Nanobioengineered Interfaces Utilizing Quaternary Nanocomposite for Highly Efficient and Selective Electrochemical Biosensing of Urea},
  journal = {Langmuir},
  year = {2024},
  doi = {10.1021/acs.langmuir.4c02457}
}
Kostenlos starten →