Electronic Tongue Based on ZnO/ITO@glass for Electrochemical Monitoring of Spiciness Levels
Langmuir · 27.02.2024 · 40 (8) · 4434-4446
DOI: 10.1021/acs.langmuir.3c03763 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 12.02.2024. Verfasst von Shahzad Ahmed und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metallurgical and Materials Engineering, Indian Institute of Technology Jodhpur, Jodhpur, Rajasthan342030, India. Hauptthemen laut MEDLINE: Capsaicin, Zinc Oxide. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 85 Literaturangaben. Gefördert von: Science and Engineering Research Board, Indian Institute of Technology Jodhpur, Department of Science and Technology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
Capsaicin, a chemical compound present in chili peppers, is widely acknowledged as the main contributor to the spicy and hot sensations encountered during consumption. Elevated levels of capsaicin can result in meals being excessively spicy, potentially leading to health issues, such as skin burning, irritation, increased heart rate and circulation, and discomfort in the gastrointestinal system and even inducing nausea or diarrhea. The level of spiciness that individuals can tolerate may vary, so what may be considered incredibly hot for one person could be mild for another. To ensure food safety, human healthcare, regulatory compliance, and quality control in spicy food products, capsaicin levels must be measured. For these purposes, a reliable and stable sensor is required to quantify the capsaicin level. To leverage the effect of zinc oxide (ZnO), herein, we demonstrated the one-step fabrication process of an electronic tongue (E-Tongue) based on an electrochemical biosensor for the determination of capsaicin. ZnO was electrodeposited on the indium tin oxide (ITO) surface. The biosensor demonstrated the two notable linear ranges from 0.01 to 50 μM and from 50 to 500 μM with a limit of detection (LOD) of 2.1 nM. The present study also included the analysis of real samples, such as green chilis, red chili powder, and dried red chilis, to evaluate their spiciness levels. Furthermore, the E-Tongue exhibited notable degrees of sensitivity, selectivity, and long-term stability for a duration of more than a month. The development of an E-Tongue for capsaicin real-time monitoring as a point-of-care (POC) device has the potential to impact various industries and improve safety, product quality, and healthcare outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Metallurgical and Materials Engineering, Indian Institute of Technology Jodhpur, Jodhpur, Rajasthan342030, India.
- The Institute for Lasers, Photonics, and Biophotonics/Chemistry, The State University of New York at Buffalo, 458 NSC Building Buffalo, Buffalo, New York 14260, United States.
- Department of Chemical Engineering, Indian Institute of Technology Jodhpur, Jodhpur, Rajasthan342030, India.
- Metallizing Equipment Co. Pvt. Ltd. (MECPL), Jodhpur 342012, Rajasthan, India.
ORCID-Profile: Shahzad Ahmed, Arshiya Ansari, Moin Ali Siddiqui, Prashant Kumar Gupta
Förderung
- Science and Engineering Research Board
- Indian Institute of Technology Jodhpur
- Department of Science and Technology, Ministry of Science and Technology, India
- Ministry of Education, India
- SEED
- SRG
Zitieren
APA
Ahmed, S., Ansari, A., Bishwanathan, S., Siddiqui, M. A., Tailor, S., Gupta, P. K., Negi, D. S., & Ranjan, P. (2024). Electronic Tongue Based on ZnO/ITO@glass for Electrochemical Monitoring of Spiciness Levels. Langmuir, 40(8), 4434-4446. https://doi.org/10.1021/acs.langmuir.3c03763
Vancouver
Ahmed S, Ansari A, Bishwanathan S, Siddiqui MA, Tailor S, Gupta PK, et al. Electronic Tongue Based on ZnO/ITO@glass for Electrochemical Monitoring of Spiciness Levels. Langmuir. 2024;40(8):4434-4446. doi:10.1021/acs.langmuir.3c03763
BibTeX
@article{Ahmed2024,
author = {Ahmed, Shahzad and Ansari, Arshiya and Bishwanathan, Shashwat and Siddiqui, Moin Ali and Tailor, Satish and Gupta, Prashant Kumar and Negi, Devendra Singh and Ranjan, Pranay},
title = {Electronic Tongue Based on ZnO/ITO@glass for Electrochemical Monitoring of Spiciness Levels},
journal = {Langmuir},
year = {2024},
volume = {40},
number = {8},
pages = {4434--4446},
doi = {10.1021/acs.langmuir.3c03763}
}
EUVIMED