EUVIMEDEUVIMED entdecken
Crossref

Highly Sensitive Detection of Formaldehyde by Laser-Induced Graphene-Coated Silver Nanoparticles Electrochemical Sensing Electrodes

Jianyue Chen iD, Yunhan Ling, Xiaoming Yuan, Yuyang He, Shilin Li, Guan Wang, Zhengjun Zhang iD, Guixin Wang

Langmuir · 12.09.2023 · 39 (36) · 12762-12773

DOI: 10.1021/acs.langmuir.3c01472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, online erschienen am 29.08.2023. Verfasst von Jianyue Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical Engineering, Sichuan University, Chengdu 610065, China. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Department of Science and Technology of Sichuan Province, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Formaldehyde (HCHO) poses a grave threat to human health because of its toxicity, but its accurate, sensitive, and rapid detection in aqueous solutions remains a major challenge. This study proposes a novel electrochemical sensor composed of a graphene-based electrode that is prepared via laser induction technology. The precursor material, polyimide, is modified via the metal ion exchange method, and the detective electrode is coated with graphene and silver nanoparticles. And the special structure of graphene-coated Ag was demonstrated using scanning electron microscopy (SEM) and high-resolution transmission electron microscopy (HRTEM), and X-ray diffraction (XRD), Fourier transform infrared (FT-IR), and X-ray photoelectron spectroscopy (XPS) results show that graphene provides more sites for Ag NRs to be exposed and increases the surface area of contact between the solution and the detection object. In addition, differential pulse voltammetry (DPV) analysis exhibits high linearity over the HCHO concentration range from 0.05 to 5 μg/mL, with a detection limit of 0.011 μg/mL (S/N = 3). The Ag NPs in the electrochemical reaction will adsorb the intermediate •CO and •OH, catalyze their combination, and finally convert to CO2 and H2O, respectively. A microdetection device, specially designed for use with commercial micro-workstations, is employed to fully demonstrate the practical application of the electrode, which paves a way for developing formaldehyde electrochemical sensors.

Autor:innen und Institutionen

  • School of Chemical Engineering, Sichuan University, Chengdu 610065, China.
  • Laboratory of Advanced Materials, School of Materials Sciences and Engineering, Tsinghua University, Beijing 100084, China.

ORCID-Profile: Jianyue Chen, Zhengjun Zhang

Förderung

  • Department of Science and Technology of Sichuan Province
  • National Natural Science Foundation of China

Zitieren

APA

Chen, J., Ling, Y., Yuan, X., He, Y., Li, S., Wang, G., Zhang, Z., & Wang, G. (2023). Highly Sensitive Detection of Formaldehyde by Laser-Induced Graphene-Coated Silver Nanoparticles Electrochemical Sensing Electrodes. Langmuir, 39(36), 12762-12773. https://doi.org/10.1021/acs.langmuir.3c01472

Vancouver

Chen J, Ling Y, Yuan X, He Y, Li S, Wang G, et al. Highly Sensitive Detection of Formaldehyde by Laser-Induced Graphene-Coated Silver Nanoparticles Electrochemical Sensing Electrodes. Langmuir. 2023;39(36):12762-12773. doi:10.1021/acs.langmuir.3c01472

BibTeX
@article{Chen2023,
  author = {Chen, Jianyue and Ling, Yunhan and Yuan, Xiaoming and He, Yuyang and Li, Shilin and Wang, Guan and Zhang, Zhengjun and Wang, Guixin},
  title = {Highly Sensitive Detection of Formaldehyde by Laser-Induced Graphene-Coated Silver Nanoparticles Electrochemical Sensing Electrodes},
  journal = {Langmuir},
  year = {2023},
  volume = {39},
  number = {36},
  pages = {12762--12773},
  doi = {10.1021/acs.langmuir.3c01472}
}
Kostenlos starten →