Effects of Polarizer–Analyzer Configurations for FTIR Spectroscopy: Implications for Multiple Polarization Algorithms
The Journal of Physical Chemistry B · 02.05.2024 · 128 (17) · 4123-4138
DOI: 10.1021/acs.jpcb.4c00854 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Physical Chemistry B, online erschienen am 23.04.2024. Verfasst von Callum Gassner und 6 weiteren Autor:innen. Beteiligte Einrichtung: Monash Biospectroscopy Group, School of Chemistry, Monash University, Clayton 3800, Australia. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
Polarized Fourier transform infrared (p-FTIR) spectroscopy is a widely used technique for determining orientational information in thin organic materials. Conventionally, a single polarizer is placed in the path of the incident light (termed the polarizer). Occasionally, a second polarizer is also placed after the sample (referred to as the analyzer). However, this polarizer-analyzer configuration has the potential to induce polarization-dependent variances in the final spectra beyond those that are expected, i.e., the squared-cosine relationship of absorptance with respect to polarization angle is no longer accurate. These variances are due to changes in the polarization state of the transmitted light induced by the sample and have yet to be explored in the context of p-FTIR. Consequently, this study employs both theoretical and experimental approaches to identify the effects of including a second polarizer in p-FTIR analyses of anisotropic organic samples. For thin samples, the most significant spectral variance arising from only birefringence is observed on the shoulders of the dichroic peaks. By adopting a crossed polarizer configuration, it is shown that there is potential to identify anisotropy of samples that are generally considered too thick for p-FTIR analysis by exploiting this feature. Furthermore, the squared-cosine relationship of absorptance with respect to the polarization angle is also shown to be inapplicable when a second parallel-oriented polarizer is included. Accordingly, a function that accounts for the second polarizer is proposed for multiple polarization techniques.
Autor:innen und Institutionen
- Monash Biospectroscopy Group, School of Chemistry, Monash University, Clayton 3800, Australia.
- IITB-Monash Research Academy, Indian Institute of Technology Bombay, Mumbai 400076, India.
- Infrared Microspectroscopy (IRM) Beamline, ANSTO─Australian Synchrotron, Clayton 3168, Australia.
ORCID-Profile: Callum Gassner, Bayden R Wood
Zitieren
APA
Gassner, C., Dodla, A., Mclean, A., Joshi, S., Giergiel, M., Vongsvivut, J., & Wood, B. R. (2024). Effects of Polarizer–Analyzer Configurations for FTIR Spectroscopy: Implications for Multiple Polarization Algorithms. The Journal of Physical Chemistry B, 128(17), 4123-4138. https://doi.org/10.1021/acs.jpcb.4c00854
Vancouver
Gassner C, Dodla A, Mclean A, Joshi S, Giergiel M, Vongsvivut J, et al. Effects of Polarizer–Analyzer Configurations for FTIR Spectroscopy: Implications for Multiple Polarization Algorithms. The Journal of Physical Chemistry B. 2024;128(17):4123-4138. doi:10.1021/acs.jpcb.4c00854
BibTeX
@article{Gassner2024,
author = {Gassner, Callum and Dodla, Ankit and Mclean, Aaron and Joshi, Sarika and Giergiel, Magdalena and Vongsvivut, Jitraporn and Wood, Bayden R},
title = {Effects of Polarizer–Analyzer Configurations for FTIR Spectroscopy: Implications for Multiple Polarization Algorithms},
journal = {The Journal of Physical Chemistry B},
year = {2024},
volume = {128},
number = {17},
pages = {4123--4138},
doi = {10.1021/acs.jpcb.4c00854}
}
EUVIMED