EUVIMEDEUVIMED entdecken
Crossref

Application of Nanosecond Pulsed Electric Field and Autofluorescence Lifetime Microscopy of FAD in Lung Cells

Kamlesh Awasthi iD, Tsai-En Wu, Hsin-Yun Hsu, Nobuhiro Ohta iD

The Journal of Physical Chemistry B · 2023

DOI: 10.1021/acs.jpcb.3c01148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Physical Chemistry B, 2023. Verfasst von Kamlesh Awasthi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Chemistry and Institute of Molecular Science, National Yang Ming Chiao Tung University, 1001 Ta-Hsueh Rd., Hsinchu 300093, Taiw…. Hauptthemen laut MEDLINE: Microscopy, Apoptosis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Ministry of Science and Technology, Taiwan, Ministry of Education, Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Exposure of nanosecond pulsed electric fields (nsPEFs) to live cells is an increasing research interest in biology and medicine. Despite extensive studies, a question still remains as to how effects of application of nsPEF on intracellular functions are different between cancerous cells and normal cells and how the difference can be detected. Herein, we have presented an approach of autofluorescence lifetime (AFL) microscopy of flavin adenine dinucleotide (FAD) to detect effects of application of nsPEF having 50 ns of a pulse width, nsPEF(50), on intracellular function in lung cancerous cells, A549 and H661, which show nsPEF(50)-induced apoptosis, and normal cells, MRC-5, in which the field effect is less or not induced. Then, the application of nsPEF(50) is shown to increase the lifetime of FAD autofluorescence in lung cancerous cells, whereas the electric field effects on the autofluorescence of FAD was not significant in normal healthy cells, which indicates that the lifetime measurements of FAD autofluorescence are applicable to detect the field-induced change in intracellular functions. Lifetime and intensity microscopic images of FAD autofluorescence in these lung cells were also acquired after exposure to the apoptosis-inducer staurosporine (STS). Then, it was found that the AFL of FAD became longer after exposure not only in the cancerous cells but also in the normal cells. These results indicate that nsPEF(50) applied to lung cells induced apoptotic cell death only in lung cancerous cells (H661 and A549) but not in lung normal cells (MRC-5), whereas STS induced apoptotic cell death both in lung cancerous cells and in lung normal cells. The lifetime microscopy of FAD autofluorescence is suggested to be very useful as a sensitive detection method of nsPEF-induced apoptotic cell death.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroscopyApoptosisCell MembraneLung

Autor:innen und Institutionen

  • Department of Applied Chemistry and Institute of Molecular Science, National Yang Ming Chiao Tung University, 1001 Ta-Hsueh Rd., Hsinchu 300093, Taiwan.
  • Center for Emergent Functional Matter Science, National Yang Ming Chiao Tung University, 1001 Ta-Hsueh Rd., Hsinchu 300093, Taiwan.

ORCID-Profile: Kamlesh Awasthi, Nobuhiro Ohta

Förderung

  • Ministry of Science and Technology, Taiwan
  • Ministry of Education, Taiwan

Zitieren

APA

Awasthi, K., Wu, T. E., Hsu, H. Y., & Ohta, N. (2023). Application of Nanosecond Pulsed Electric Field and Autofluorescence Lifetime Microscopy of FAD in Lung Cells. The Journal of Physical Chemistry B. https://doi.org/10.1021/acs.jpcb.3c01148

Vancouver

Awasthi K, Wu TE, Hsu HY, Ohta N. Application of Nanosecond Pulsed Electric Field and Autofluorescence Lifetime Microscopy of FAD in Lung Cells. The Journal of Physical Chemistry B. 2023. doi:10.1021/acs.jpcb.3c01148

BibTeX
@article{Awasthi2023,
  author = {Awasthi, Kamlesh and Wu, Tsai-En and Hsu, Hsin-Yun and Ohta, Nobuhiro},
  title = {Application of Nanosecond Pulsed Electric Field and Autofluorescence Lifetime Microscopy of FAD in Lung Cells},
  journal = {The Journal of Physical Chemistry B},
  year = {2023},
  doi = {10.1021/acs.jpcb.3c01148}
}
Kostenlos starten →