EUVIMEDEUVIMED entdecken
Crossref

Mitochondrial-Targeted Ratiometric Near-Infrared Fluorescence Probe for Monitoring Nitric Oxide in Rheumatoid Arthritis

Tingting Han, Ye Sun, Chao Zhao, Hai-Yan Wang, Hui Yu, Yi Liu iD

Journal of Medicinal Chemistry · 14.03.2024 · 67 (5) · 4026-4035

DOI: 10.1021/acs.jmedchem.3c02344 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medicinal Chemistry, online erschienen am 15.02.2024. Verfasst von Tingting Han und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering, China Pharmaceutical University, Nanjing 211198, China. Hauptthemen laut MEDLINE: Nitric Oxide, Arthritis, Rheumatoid. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 71 Literaturangaben. Gefördert von: Jiangsu Planned Projects for Postdoctoral Research Funds, Double First Class University Plan, Six Talent Peaks Project in Jiangsu Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rheumatoid arthritis (RA) is a destructive autoimmune disease, where nitric oxide (NO) is closely implicated in the inflammatory processes of RA. Therefore, direct visualization of NO is essential to assess the pathological changes in RA. Herein, a mitochondrial-targeted near-infrared ratiometric fluorescent probe (NFL-NH2), based on the intramolecular charge transfer effect, was synthesized and applied to monitor the changes of NO content in early RA. Specially, probe NFL-NH2 showed a 44-fold fluorescent intensity ratio (I705/I780) response toward NO with a detection limit of 0.536 nM, enabling qualitative and quantitative analysis of NO. Additionally, NFL-NH2 can accurately target mitochondria and sensitively detect exogenous and endogenous NO in RAW 264.7 cells. Notably, in vivo RA monitoring assays demonstrated that NFL-NH2 can rapidly detect NO levels associated with the inflammatory damage degree in RA mice models by ratiometric fluorescence imaging. These results validate that NFL-NH2 holds significant potential for diagnosing NO-mediated RA diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nitric OxideArthritis, RheumatoidAnimalsMiceLimit of DetectionMicroscopy, FluorescenceFluorescent DyesMitochondria

Substanzen

Nitric OxideFluorescent Dyes

Autor:innen und Institutionen

  • School of Engineering, China Pharmaceutical University, Nanjing 211198, China.
  • School of Mechanical Engineering, Southeast University, Nanjing 211189, China.

ORCID-Profile: Yi Liu

Förderung

  • Jiangsu Planned Projects for Postdoctoral Research Funds
  • Double First Class University Plan
  • Six Talent Peaks Project in Jiangsu Province
  • National Natural Science Foundation of China

Zitieren

APA

Han, T., Sun, Y., Zhao, C., Wang, H. Y., Yu, H., & Liu, Y. (2024). Mitochondrial-Targeted Ratiometric Near-Infrared Fluorescence Probe for Monitoring Nitric Oxide in Rheumatoid Arthritis. Journal of Medicinal Chemistry, 67(5), 4026-4035. https://doi.org/10.1021/acs.jmedchem.3c02344

Vancouver

Han T, Sun Y, Zhao C, Wang HY, Yu H, Liu Y. Mitochondrial-Targeted Ratiometric Near-Infrared Fluorescence Probe for Monitoring Nitric Oxide in Rheumatoid Arthritis. Journal of Medicinal Chemistry. 2024;67(5):4026-4035. doi:10.1021/acs.jmedchem.3c02344

BibTeX
@article{Han2024,
  author = {Han, Tingting and Sun, Ye and Zhao, Chao and Wang, Hai-Yan and Yu, Hui and Liu, Yi},
  title = {Mitochondrial-Targeted Ratiometric Near-Infrared Fluorescence Probe for Monitoring Nitric Oxide in Rheumatoid Arthritis},
  journal = {Journal of Medicinal Chemistry},
  year = {2024},
  volume = {67},
  number = {5},
  pages = {4026--4035},
  doi = {10.1021/acs.jmedchem.3c02344}
}
Kostenlos starten →