HiFiPL-Bench: A Fidelity-First and Bias-Aware Benchmark for Diagnosing Protein–Ligand Scoring Functions
Journal of Chemical Information and Modeling · 18.11.2026
DOI: 10.1021/acs.jcim.6c03060 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Chemical Information and Modeling, online erschienen am 18.11.2026. Verfasst von Mengguang Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Medical College, Guizhou University, Guiyang, Guizhou550025, China. Die Arbeit nennt 58 Literaturangaben.
Abstract (Originalsprache)
Accurate prediction of protein–ligand binding affinities is fundamental to structure-based drug design, yet existing benchmarks are often limited by outdated structural coverage, uncertain local structural fidelity, and physicochemical or protocol-dependent bias. Here, we present HiFiPL-Bench, a fidelity-first and bias-aware benchmark curated from RCSB PDB and BindingDB through hierarchical filtering, manual electron-density validation, affinity verification, and property-matched decoy generation. Across nine representative scoring functions, HiFiPL-Bench revealed reduced performance in scoring, ranking, and most docking evaluations relative to CASF-2016, whereas a controlled screening-like task using computationally generated property-matched decoys produced model-specific gains and losses that altered relative rankings rather than uniformly lowering performance. Model-specific overlap and deoverlap analyses further showed that documented development-data exposure differed substantially among methods and that deoverlapped sensitivity analyses affected models and evaluation tasks nonuniformly. Together, these findings indicate that performance estimates remain sensitive to starting-structure curation, task-specific preparation, data set composition, decoy design, benchmark protocol, and recoverable development-data exposure. HiFiPL-Bench therefore provides a reusable diagnostic framework for evaluating scoring-function performance in a structurally curated and bias-aware benchmark setting.
Autor:innen und Institutionen
- Medical College, Guizhou University, Guiyang, Guizhou550025, China.
ORCID-Profile: Xiaodong Ren
Zitieren
APA
Liu, M., Ren, X., Jin, P., Zhai, L., Xiao, R., & Zhang, Y. (2026). HiFiPL-Bench: A Fidelity-First and Bias-Aware Benchmark for Diagnosing Protein–Ligand Scoring Functions. Journal of Chemical Information and Modeling. https://doi.org/10.1021/acs.jcim.6c03060
Vancouver
Liu M, Ren X, Jin P, Zhai L, Xiao R, Zhang Y. HiFiPL-Bench: A Fidelity-First and Bias-Aware Benchmark for Diagnosing Protein–Ligand Scoring Functions. Journal of Chemical Information and Modeling. 2026. doi:10.1021/acs.jcim.6c03060
BibTeX
@article{Liu2026,
author = {Liu, Mengguang and Ren, Xiaodong and Jin, Pengyao and Zhai, Likang and Xiao, Rugui and Zhang, Yali},
title = {HiFiPL-Bench: A Fidelity-First and Bias-Aware Benchmark for Diagnosing Protein–Ligand Scoring Functions},
journal = {Journal of Chemical Information and Modeling},
year = {2026},
doi = {10.1021/acs.jcim.6c03060}
}
EUVIMED