EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AGENTi: APCI-ESI Analyte Ionization Fidelity Pre-Screening Workflow using Multimodel Inference

Mithony Keng iD, Kenneth M Merz

Journal of Chemical Information and Modeling · 2026

DOI: 10.1021/acs.jcim.6c01085 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Chemical Information and Modeling, 2026. Verfasst von Mithony Keng und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Michigan State University, East Lansing48824, Michigan, United States. Hauptthemen laut MEDLINE: Spectrometry, Mass, Electrospray Ionization, Workflow. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, NIH.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ionization sources convert neutral analytes into ions, enabling their subsequent separation and detection by mass spectrometry. Depending on the technique, this mechanism occurs within a solution or in the gas phase. The two most common methods to generate ions are electrospray ionization (ESI) and atmospheric-pressure chemical ionization (APCI), respectively. Both ESI and APCI can generate the same resultant ion species; however, it has been shown that preferential charge sites can change in response to an ionization source environment. Therefore, an additional quality control is warranted a priori to delineate erroneous analyte identification and/or unequivocal structural assignment. For protonation, protomer fidelity can be assessed by comparing the ion-mobility collision cross section (CCS) values obtained for both ESI and APCI. In this work, we utilized proxy standards (i.e., controls) derived from the available literature to develop a proof-of-concept multimodel inference application called AGENTi to probe differences in ionization for high-throughput protomer shift exploratory analysis. AGENTi uses in sequence the TensorFlow Autoencoder anomaly detection and the YDF Gradient Boosted Tree machine learning frameworks to generate more balanced and robust anomaly scores. We found that using a multimodel screening approach can reduce false positive capture at an acceptable loss of true positives. Moreover, we expect to achieve a better recovery of true positives with an improvement on the current Gradient Boosted Tree regression model for ΔCCS prediction as more ESI-APCI dual data are obtained for training. In all, we demonstrated in this pilot study that our foundation model for a priori probing of ionization pathway fidelity is feasible and efficient with AGENTi. The AGENTi prototype application and documentation are accessible at https://github.com/mitkeng/AGENTi.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrometry, Mass, Electrospray IonizationWorkflowAutoencoderAtmospheric PressureBoosting Machine Learning Algorithms

Autor:innen und Institutionen

  • Department of Chemistry, Michigan State University, East Lansing48824, Michigan, United States.

ORCID-Profile: Mithony Keng

Förderung

  • NIEHS NIH HHS
  • NIH

Zitieren

APA

Keng, M., & Merz, K. M. (2026). AGENTi: APCI-ESI Analyte Ionization Fidelity Pre-Screening Workflow using Multimodel Inference. Journal of Chemical Information and Modeling. https://doi.org/10.1021/acs.jcim.6c01085

Vancouver

Keng M, Merz KM. AGENTi: APCI-ESI Analyte Ionization Fidelity Pre-Screening Workflow using Multimodel Inference. Journal of Chemical Information and Modeling. 2026. doi:10.1021/acs.jcim.6c01085

BibTeX
@article{Keng2026,
  author = {Keng, Mithony and Merz, Kenneth M},
  title = {AGENTi: APCI-ESI Analyte Ionization Fidelity Pre-Screening Workflow using Multimodel Inference},
  journal = {Journal of Chemical Information and Modeling},
  year = {2026},
  doi = {10.1021/acs.jcim.6c01085}
}
Kostenlos starten →