Rapid, Sensitive, and Specific Microbial Whole-Cell Biosensor for the Detection of Histamine: A Potential Food Toxin
Journal of Agricultural and Food Chemistry · 11.12.2024 · 72 (49) · 27466-27478
DOI: 10.1021/acs.jafc.4c06315 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Agricultural and Food Chemistry, online erschienen am 23.10.2024. Verfasst von Ankita Bhatt und 2 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Biology Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Histamine, Pseudomonas putida, Food Contamination. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 104 Literaturangaben. Gefördert von: Uttarakhand State Council for Science and Technology, Ministry of Education, India.
Abstract (Originalsprache)
Histamine is a biogenic amine; its level indicates food quality, as elevated levels cause food poisoning. Therefore, monitoring food at each step during processing until it reaches the consumer is crucial, but current techniques are complicated and time-consuming. Here, we designed a Pseudomonas putida whole-cell biosensor using a histamine-responsive genetic element expressing a fluorescent protein in the presence of the cognate target. We improved the performance of the proposed biosensor by optimizing the chassis, genetic regulatory element, and reporter gene. A sensitive and rapid biosensor variant was obtained with a limit of detection (LOD) of 0.39 ppm, manifesting a linear response (R2 = 0.98) from 0.28 to 18 ppm in 90 min. The biosensor showed minimal cross-reactivity with other biogenic amines and amino acids prevalent in food, making it highly specific. The biosensor effectively quantified histamine in spiked fish, prawn, and wine samples with a satisfactory recovery. Additionally, a colorimetric sensor variant PAlacZ was developed enabling histamine quantification in seafood via a smartphone application, with an LODgray of 0.23 ppm, exhibiting a linear response from 0 to 2.24 ppm. Overall, this study reports an efficient, specific, and highly sensitive biosensor with strong potential for the on-site detection of histamine, ensuring food safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemical Biology Lab, Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India.
ORCID-Profile: Naveen K Navani
Förderung
- Uttarakhand State Council for Science and Technology
- Ministry of Education, India
Zitieren
APA
Bhatt, A., Jain, S., & Navani, N. K. (2024). Rapid, Sensitive, and Specific Microbial Whole-Cell Biosensor for the Detection of Histamine: A Potential Food Toxin. Journal of Agricultural and Food Chemistry, 72(49), 27466-27478. https://doi.org/10.1021/acs.jafc.4c06315
Vancouver
Bhatt A, Jain S, Navani NK. Rapid, Sensitive, and Specific Microbial Whole-Cell Biosensor for the Detection of Histamine: A Potential Food Toxin. Journal of Agricultural and Food Chemistry. 2024;72(49):27466-27478. doi:10.1021/acs.jafc.4c06315
BibTeX
@article{Bhatt2024,
author = {Bhatt, Ankita and Jain, Shubham and Navani, Naveen K},
title = {Rapid, Sensitive, and Specific Microbial Whole-Cell Biosensor for the Detection of Histamine: A Potential Food Toxin},
journal = {Journal of Agricultural and Food Chemistry},
year = {2024},
volume = {72},
number = {49},
pages = {27466--27478},
doi = {10.1021/acs.jafc.4c06315}
}
EUVIMED