A Hybrid Manganese Halide Scintillator with a High X-ray Absorption Coefficient for X-ray Imaging
Inorganic Chemistry · 11.05.2026 · 65 (18) · 10407-10415
DOI: 10.1021/acs.inorgchem.6c01459 ↗Kurz gefasst
Fachartikel in der Zeitschrift Inorganic Chemistry, online erschienen am 23.04.2026. Verfasst von Zixian Ye und 10 weiteren Autor:innen. Beteiligte Einrichtung: College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, P. R. China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Beijing Nova Program, Wuhan Harlan Medical Technology Co., Ltd.
Abstract (Originalsprache)
Manganese-based hybrid metal halides are attractive for scintillator applications due to their high emission efficiency and good stability. However, most high-performance manganese scintillators rely on bulky and complex organic cations as A-site components, which reduce the lattice density and compromise X-ray absorption. To address this issue, we employed a small piperidinium cation (C5H12N+) to synthesize a zero-dimensional manganese halide, (C5H12N)2MnBr4, via solvent evaporation. This material shows green Mn2+ emission but suffers from concentration quenching, giving a low PLQY of 23.86%. Through Cd2+ alloying, the optimized (C5H12N)2MnBr4: 20%Cd achieves a markedly enhanced PLQY of 78.54%. As a scintillator, it exhibits excellent X-ray absorption─among the highest reported for hybrid manganese scintillators─and a high light yield of 21086 photons/MeV. This improvement results from the synergy between the small A-site cation (providing a compact lattice for strong absorption) and Cd2+ alloying (suppressing concentration quenching). A 10 × 10 cm flexible film fabricated by incorporating the alloyed powder into a TPU matrix shows outstanding radiation stability and a high X-ray imaging resolution of 14 lp mm-1. The combination of strong X-ray absorption, enhanced luminescence, and solution processability opens new opportunities for low-cost, large-area, flexible X-ray detectors and imaging.
Autor:innen und Institutionen
- College of Materials Science and Engineering, Beijing University of Technology, Beijing 100124, P. R. China.
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, P. R. China.
- Beijing Glass Research Institute Co., Ltd., Beijing 101111, China.
- Hubei Key Laboratory of Low Dimensional Optoelectronic Materials and Devices, Hubei University of Arts and Science, Xiangyang 401053, P. R. China.
ORCID-Profile: Pengyu Zhang, Shengcheng Mao, Qingsong Hu, Yiping Du, Jiawen Xiao
Förderung
- National Natural Science Foundation of China
- Beijing Nova Program
- Wuhan Harlan Medical Technology Co., Ltd
Zitieren
APA
Ye, Z., Zhang, P., Guan, H., Cai, Z., Song, J., Zhang, C., Mao, S., Hu, Q., Du, Y., Yan, Z., & Xiao, J. (2026). A Hybrid Manganese Halide Scintillator with a High X-ray Absorption Coefficient for X-ray Imaging. Inorganic Chemistry, 65(18), 10407-10415. https://doi.org/10.1021/acs.inorgchem.6c01459
Vancouver
Ye Z, Zhang P, Guan H, Cai Z, Song J, Zhang C, et al. A Hybrid Manganese Halide Scintillator with a High X-ray Absorption Coefficient for X-ray Imaging. Inorganic Chemistry. 2026;65(18):10407-10415. doi:10.1021/acs.inorgchem.6c01459
BibTeX
@article{Ye2026,
author = {Ye, Zixian and Zhang, Pengyu and Guan, Haoyang and Cai, Zhuoer and Song, Jing and Zhang, Chunsheng and Mao, Shengcheng and Hu, Qingsong and Du, Yiping and Yan, Zhengguang and Xiao, Jiawen},
title = {A Hybrid Manganese Halide Scintillator with a High X-ray Absorption Coefficient for X-ray Imaging},
journal = {Inorganic Chemistry},
year = {2026},
volume = {65},
number = {18},
pages = {10407--10415},
doi = {10.1021/acs.inorgchem.6c01459}
}
EUVIMED