EUVIMEDEUVIMED entdecken
Crossref

Electrochemical Detection of Chloramphenicol with Different Modified Electrodes Based on the Metal-Cyclotriveratrylene Framework and Mesoporous Carbon

Yu-Ying Li, Xia Niu, Wen-Yuan Pei, Jian-Fang Ma iD

Inorganic Chemistry · 21.04.2025 · 64 (15) · 7543-7551

DOI: 10.1021/acs.inorgchem.5c00477 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Inorganic Chemistry, online erschienen am 04.04.2025. Verfasst von Yu-Ying Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Ch…. Hauptthemen laut MEDLINE: Chloramphenicol, Electrochemical Techniques, Metal-Organic Frameworks, Carbon. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: Jilin Provincial Scientific and Technological Development Program, Education Department of Jilin Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Design of high-performance electrochemical sensors for detection of antibiotics is greatly desirable for human health and ecological safety. Herein, a new metal-organic framework (MOF), namely, [Zn2L(PDC)2(H2O)2]·3H2O (1), was synthesized with isophthalic acid (H2PDC), Zn(II) cation, and cyclotriveratrylene-based ligand (L). By mechanical milling, 1 was incorporated with mesoporous carbon (MC) to produce 1@MC. Subsequently, 1@MC was decorated on different bare electrodes (glass carbon (GC), Au, Pt, or W electrode). The introduction of MC significantly improved the conductivity and the current response intensity for determination of chloramphenicol (CAP). Among these sensors, the current responses of CAP on 1@MC(1:2)/GCE and 1@MC(1:2)/Au were more intense. Markedly, they exhibited relatively wide linear ranges (0.5-400 μM on 1@MC(1:2)/GCE and 1-400 μM on 1@MC(1:2)/Au) and low limits of detection (0.15 μM on 1@MC(1:2)/GCE and 0.48 μM on 1@MC(1:2)/Au). Particularly, they can be used for the measurement of CAP in eye drop and milk sample with fine recoveries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChloramphenicolElectrochemical TechniquesMetal-Organic FrameworksCarbonAnti-Bacterial AgentsElectrodesPorosityLimit of DetectionMilkMolecular StructureAnimals

Substanzen

ChloramphenicolMetal-Organic FrameworksCarbonAnti-Bacterial Agents

Autor:innen und Institutionen

  • Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Department of Chemistry, Northeast Normal University, Changchun 130024, China.
  • Department of Public Health and Preventive Medicine, Changzhi Medical College, Changzhi 046000, China.

ORCID-Profile: Jian-Fang Ma

Förderung

  • Jilin Provincial Scientific and Technological Development Program
  • Education Department of Jilin Province

Zitieren

APA

Li, Y. Y., Niu, X., Pei, W. Y., & Ma, J. F. (2025). Electrochemical Detection of Chloramphenicol with Different Modified Electrodes Based on the Metal-Cyclotriveratrylene Framework and Mesoporous Carbon. Inorganic Chemistry, 64(15), 7543-7551. https://doi.org/10.1021/acs.inorgchem.5c00477

Vancouver

Li YY, Niu X, Pei WY, Ma JF. Electrochemical Detection of Chloramphenicol with Different Modified Electrodes Based on the Metal-Cyclotriveratrylene Framework and Mesoporous Carbon. Inorganic Chemistry. 2025;64(15):7543-7551. doi:10.1021/acs.inorgchem.5c00477

BibTeX
@article{Li2025,
  author = {Li, Yu-Ying and Niu, Xia and Pei, Wen-Yuan and Ma, Jian-Fang},
  title = {Electrochemical Detection of Chloramphenicol with Different Modified Electrodes Based on the Metal-Cyclotriveratrylene Framework and Mesoporous Carbon},
  journal = {Inorganic Chemistry},
  year = {2025},
  volume = {64},
  number = {15},
  pages = {7543--7551},
  doi = {10.1021/acs.inorgchem.5c00477}
}
Kostenlos starten →